2.2.5 Master LED Indication

After completing the interface connection and power on the units, users can inspect the LED on
the front panel. The Master is consisted of two parts of features. One is controller for alarm,
subtend and optical feature. The others are DSL feature. The status of these features is shown in
Table 2-2.
PWR
M_ACT
M_CR
M_MJ
M_MN
LNK
Gx
1000
FDX

Figure 2-6. Master subtend connection

Table 2-2. IP DSLAM master DSL LED descriptions

Green The Power LED is on when Power is applied.
OFF The Power is not applied.
Green Blink when Master is active.
OFF OFF when system is hanged.
Green Master critical alarm is present.
OFF No critical alarm is present to system.
Green Master Major Alarm is present.
OFF No major alarm is present to system.
Green Master Minor Alarm is present.
OFF No minor alarm is present to system.
Green Subtend interface by GE Interface.
Green when Ethernet link is established Blinks during data
transmitting/receiving.
OFF OFF means No Ethernet link established.
Green The speed for Ethernet is 1000Mbps when LNK LED is ON.
OFF The speed for Ethernet is 10/100Mbps when LNK LED is ON.
Green The Ethernet is in full duplex mode when LNK LED is ON.
OFF The Ethernet is in half duplex mode when LNK LED is ON.