Ordering Information - Toshiba LF434 /LF620 Manual

Electromagnetic flowmeter
Hide thumbs Also See for LF434 /LF620:

Advertisement

TIC-LF434H
Table 4. Flow Rate and Flow velocity (SI unit)
Size
(mm)
0.1 m/s
0.3 m/s
15
0.06362
0.1908
25
0.1767
0.5301
*1
32
0.2895
0.8686
0.4523
40
1.357
50
0.7067
2.120
*1
65
1.195
3.583
80
1.809
5.428
2.827
100
8.482
6.361
150
19.08
200
11.31
33.93
250
17.67
53.01
300
25.45
76.34
34.64
350
103.9
400
45.23
135.7
450
57.25
171.7
500
70.69
212.1
600
101.8
305.4
Note 1: JIS 10K flange type only.
Calibration Range
If the calibration range is not specified, the standard
range as shown below will be used. If the range is
specified, we will use the specified range for
calibration.
Table 5. Standard Flow Range
Meter size
Standard flow range
Flow
Flow
mm (inch)
rate
velocity
(m³/h)
(m/s)
15 (1/2)
2
3.144
25 (1)
6
3.395
32 (1 1/4)
10
3.454
40 (1 1/2)
15
3.316
50 (2)
25
3.537
65 (2 1/2)
40
3.348
80 (3)
60
3.316
100 (4)
100
3.537
150 (6)
200
3.144
200 (8)
300
2.653
250 (10)
600
3.395
300 (12)
900
3.537
350 (14)
1,200
3.465
400 (16)
1,600
3.537
450 (18)
2,500
4.366
500(20)
3,000
4.244
600(24)
4,000
3.930
Note: The unit of "gal/min" is not exchanged
(converted) by "m
10
3
Unit: m
/h
Flow rate
1.0 m/s
3.0 m/s
10 m/s
0.6361
1.908
6.361
1.767
5.301
17.67
2.895
8.686
28.95
13.57
4.523
45.23
7.067
21.20
70.67
11.95
35.83
119.5
18.09
54.28
180.9
84.82
28.27
282.7
190.8
63.61
636.1
113.1
229.3
1,131
176.7
530.1
1,767
254.5
763.4
2,545
1,039
346.4
3,464
452.3
1,357
4,523
572.5
1,717
5,725
706.9
2,112
7,069
1,018
3,054
10,180
Flow
Flow
rate
velocity
(gal/min)
(ft/s)
25
29.283
75
31.625
125
32.171
175
28.826
300
31.625
475
29.629
650
26.766
1,000
26.354
2,500
29.283
4,500
29.649
7,000
29.517
10,000
28.283
12,000
25.817
16,000
26.354
20,000
26.029
25,000
26.354
40,000
29.283
3
/h".
About establishment environment
Do not store or install the flowmeter:
• Where there is direct sunlight.
• Where excessive vibration or mechanical shock
occurs.
• Where high temperature or high humidity conditions
exist.
• Where corrosive atmospheres exist.
• Places that can be submerged under water.
• When placing the flowmeter temporarily on the floor,
support it, i.e., with a block so that the flowmeter
does not topple over.
In areas like the following, there may be the case that
infrared switches do not function correctly. (If these are
unavoidable, use an appropriate cover.)
(1) Where unit (operation panel) is exposed to direct
sunlight, reflection of light onto window pane and
diffused light reflection.
(2) Where smoke and steam may occur.
(3) Where exposed to direct snow, ice or mud.

Ordering Information

1. When ordering the LF430 series flowmeters, refer to
Tables 6 and 7 (Type Specification Codes).
An entry must be made for each of the columns in
each of these tables.
2. Fluid characteristics:
(1) Type of fluid to be measured and its characteristics
(2) Fluid temperature
(3) Fluid pressure
(4) Electrical conductivity of the fluid
3. Measuring range
4. I/O function setting
5. Ordering scope:
Flow calibration data: (required or not)
6. Other items
Specifications other than standard items
Consult a Toshiba representative before ordering
when choosing materials of the wetted parts such as
lining, electrodes, and grounding rings.
Toshiba International Corp. (Houston) stocks
Hazardous location certification type
flowmeters as standard inventory.