Download Print this page
Sonniger GUARD PRO Operation And Maintenance Documentation

Sonniger GUARD PRO Operation And Maintenance Documentation

Hide thumbs Also See for GUARD PRO:

Advertisement

Quick Links

Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106
Operation and Maintenance Documentation
SONNIGER Polska Sp. z o.o. Sp.K.
ul. Śląska 35/37, 81-310 Gdynia, Polska, infolinia 801 055 155, tel. + 48 58 785 34 80,
www.sonniger.com
Sąd Rejonowy Gdańsk-Północ, VIII Wydział Gospodarczy Krajowego Rejestru Sądowego, KRS 0000504509,
NIP 586 227 35 14,Regon 22154369 kapitał zakładowy: 1.655.000 PLN

Advertisement

loading
Need help?

Need help?

Do you have a question about the GUARD PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sonniger GUARD PRO

  • Page 1 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 Operation and Maintenance Documentation SONNIGER Polska Sp. z o.o. Sp.K. ul. Śląska 35/37, 81-310 Gdynia, Polska, infolinia 801 055 155, tel. + 48 58 785 34 80, www.sonniger.com Sąd Rejonowy Gdańsk-Północ, VIII Wydział...
  • Page 2 In summers, the curtains may be used as cooling devices preventing the entry of hot air from outside as well as air pollutants. The GUARD PRO industrial air curtains are designed to protect against heat losses in the gateways of buildings of medium and high capacity especially such as the followings:...
  • Page 3 GENERAL AND SAFETY PRINCIPLES The GUARD PRO air curtains are manufactured in compliance with the rules and standards concerning quality, ecology, utility and work comfort. Before starting the device be sure to read the Manual carefully.
  • Page 4 They must be assembled side-by-side to make an uninterrupted stream of air. The curtain is mounted horizontally or vertically for permanent (on the left/right side of the doorway). The GUARD PRO air curtain is advised to be wider (in case of horizontal mounting) or higher (in case of vertical mounting) than the gate way.
  • Page 5 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 Installation of connector inside the curtain Installation of connector at the back of the curtains Horizontal assembly To mount the curtain horizontally in a proper way, keep the distance of min 300mm from the rear side of the device.
  • Page 6: Controller Installation

    Power cable and a main switch are not included in the set. Also the DOORSTOP door contact switch can be installed; it turns off the GUARD PRO curtain when the door is being closed and the moment the door is being opened the GUARD PRO curtain starts operating accordingly to the parameters set in the control panel of the device.
  • Page 7 CONNECTION SCHEME FOR GUARD PRO TYPE W (WATER EXCHANGER), TYPE C (AMBIENT) WITH PANEL COMFORT (ONLY 1 UNIT FOR COMOFORT PANEL) Power supply cables not included 7.2. CONNECTION SCHEME FOR GUARD PRO TYPE E (ELECTRIC HEATER) WITH PANEL COMFORT (ONLY 1 UNIT FOR COMOFORT PANEL) Power supply cables not included...
  • Page 8 CONNECTION SCHEME FOR GUARD PRO TYPE W (WATER EXCHANGER), TYPE C (AMBIENT) WITH A CONTROL BOX MADE BY INSTALLER Power supply cables not included 7.4. CONNECTION SCHEME FOR GUARD PRO TYPE E (ELECTRIC HEATER) WITH A CONTROL BOX MADE BY INSTALLER Power supply cables not included...
  • Page 9 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 7.5. CONNECTION SCHEME FOR GUARD PRO TYPE E (ELECTRIC HEATER) WITH THE MULTI 6 CONTROL BOX (UP TO 6 UNIT) Power supply cables not included...
  • Page 10 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 7.6. CONNECTION SCHEME FOR GUARD PRO TYPE W (WATER EXCHANGER), TYPE C (AMBIENT) WITH THE MULTI 6 CONTROL BOX (UP TO 6 UNIT) Power supply cables not included...
  • Page 11: Operation And Maintenance

    Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 The Multi 6 control box allows to connect and control up to 6x GUARD PRO 200 and 6x servomotors. The control of the unit motors is via Panel COMFORT or INTELLIGENT, there is a possibility to connect DOORSTOP switch to it. The thermostat has a primary function when connected to the unit with the Doorswitch.
  • Page 12 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 PANEL INTELLIGENT – BMS-ready controller manual Panel Intelligent controls actuators/valves and regulates fan’s speed. The controller is able to connect with BMS by MODBUS RTU protocol. Functions Panel INTELLINGENT is designed for the SONNIGER products •...
  • Page 13 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 Dimensions Settings menu When Panel Intelligent is switched off, press and hold MODE for 5 seconds To change option use MODE button. To change value use +/- buttons.
  • Page 14: Spare Parts Catalogue

    Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 SPARE PARTS CATALOGUE COMPLIANCE WITH WEEE 2012/19 / EU In accordance with applicable legal regulations, at the time of purchasing new electrical or electronic equipment with the following mark:...
  • Page 15 The Claimant is obliged to give a written confirmation of the service provided. SONNIGER is entitled to refuse the warranty service if SONNIGER has not received full payment for the product complained about under the Guarantee or any previous servicing activities.
  • Page 16 Operation and Maintenance Documentation of GUARD PRO air curtains GUARD PRO v202106 WARRANTY CARD INVESTMENT NAME……………………..…………………….………………………….. UNIT TYPE………………………………………………………………………………… UNIT NUMBER…………..…………………………………………………………………... PURCHASE DATE….………………………………………………………………………. STARTUP DATE……………………………………………………………………………… INSTALLATION COMPANY DATE: NAME OF STARTUP INSTALLER:…………………………………………………… COMPANY NAME..………………………………………………………………………… …………………………………………………………………………………………………. ADDRESS:.………………………………………………………………………………..PHONE..…………………………………………………………………………………... SIGNATURE OF STARTUP INSTALLER……………..:………………………………...