Electrical installation

Electrical connections

Safety

ATTENTION
All work must be carried out by qualified persons and in compliance with existing legislation and regulations.
ATTENTION
It is important that the power is off, if you do work to the electrical components of the unit.
It is important to check that wires are not damaged or squeezed during connection and use.

Connections list

All connections are located on the top of the ventilation unit.

Electrical connection unit

Power supply

CAUTION
The power supply is plugged into a 230V socket with a safety switch. It is important that the unit has ground connection.
The ventilation unit is supplied with an EU Schuko plug for 230V
power supply.
This means that if you have not installed a shoko socket with
side earth or pin earth, an Adapter schuko plug with pin earth
must be used.
This Schuko adapter can be plugged into the ventilation unit's
Shuko plug and then into a socket with earth.
1. Connection 230V (remember electrical grounding)
2. External connections / accessories via RJ45 connector
3. Connection to PC Tool via USB connector
Schuko socket
with side earth
Schuko socket
Example of Adapter
with pin earth
Schuko plug with pin
ground
13