TROUBLESHOOTING GUIDE
FOR THE BUILT IN FIREPLACE
MODEL NUMBERS:
BF33ST/DX
BF39ST/DX
BF45ST/DX

Advertisement

loading

Summary of Contents for Dimplex BF33ST

  • Page 1 TROUBLESHOOTING GUIDE FOR THE BUILT IN FIREPLACE MODEL NUMBERS: BF33ST/DX BF39ST/DX BF45ST/DX...
  • Page 2: Troubleshooting Guide

    BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, B45DX TROUBLESHOOTING GUIDE GENERAL Service Manual Problem Cause Solution Reference Circuit breaker trips Verify unit is installed on a or fuse blows when Improper circuit current rating dedicated 15 amp circuit unit is turned on...
  • Page 3 BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX TROUBLESHOOTING GUIDE HEATER Service Manual Problem Cause Solution Reference Defective heater switch Replace heater switch Page 12 Heater is not Defective remote control kit Replace remote control kit Page 31 turning off Defective thermostat...
  • Page 4 BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX TROUBLESHOOTING GUIDE HEATER (CONTINUED) Service Manual Problem Cause Solution Reference Voltage selector switch is in Select correct voltage Blower running fast Page 3 the wrong position selector switch position Blower running Voltage selector switch is in...