NOT AVAILABLE WITH NO HEAT INSTALLATION
NOTE:
The fireplace can be wired to have a wall switch operate the heater independent of the flame
NOTE:
Before installing the unit complete the following:
1. Install main power connection with appropriate voltage as per Section C or
Section D.
2. Install a 2 conductor wire with ground (3 wires total) from the flame override switch wall
box to the junction box on the unit.
NOTE:
Use a wall switch (on/off) that is rated for a minimum of 15 amps.
120 / 240 VOLT INSTALLATIONS
1. Loosen the screw securing the junction box cover and remove the cover.
2. Remove the knockouts (if necessary) or use the provided cable clamp.
3. Pull out the three wires marked 3, 4, and G. (blue, blue, and green)
4. Remove the wire connector and separate the wires marked 3 and 4.
5. Connect the (blue) 3 wire from the unit to the (black) L1 wire from the flame override
wall switch by using a wire connector (not supplied).
6. Connect the other end of the (black) L1 wire from the flame override wall switch to
the L1 terminal of the flame override wall switch.
7. Connect the (blue) 4 wire from the unit to the (white) Neutral wire from the flame
override wall switch using a wire connector (not supplied).
8. Connect the other end of the (white) Neutral wire from the flame override wall switch
to the L2 terminal of the flame override wall switch.
9. Connect the (green) Ground wire from the unit to the (green) Ground wire from the
flame override wall switch using a wire connector (not supplied).
10. Secure the one remaining (green) Ground wire with a ground screw in the flame
override switch wall box.
11. Ensure that all connections are tight.
12. Insert all the wiring of the heater wall switch into the heater switch wall box.
13. Insert all the wiring back into the unit and secure with a cable clamp.