IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.com 7206350500R03...
CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
LISTING AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters. MODEL SPECIFICATIONS Rated Current Draw (Amps) Model Wall Remote Refractory Power Description Voltage...
SECTION B: GENERAL ELECTRICAL INFORMATION RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS For 120V installations use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply on fireplace inserts. Use the appropriate wire to meet local and national electrical codes for rated power consumption. For 208V / 240V installations use three conductor, non-metallic sheath cable with ground wire (4 wires total) for the incom- ing power supply on fireplace inserts.
Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from 240V to 120V configuration. (230 and 115 is printed on switch) Loosen the screw securing the junction box cover and remove the cover. www.dimplex.com...
Remove the knockouts (if necessary) or use the provided cable clamp. Pull out the four wires marked L1, L2, N, and G. Connect L1 (black) wire from the unit to the L1 (black) from the power supply. Connect L2 (red) and N (white) from the unit to the Neutral (white) from the power supply. Connect the ground wire (green) from the unit to the ground from the power supply.
Ensure that all connections are tight. Insert all the wiring of the main power wall switch into the main switch wall box. Insert all the wiring back into the unit and secure with a cable clamp. www.dimplex.com...
120V MAIN POWER WALL SWITCH WHITE - N WHITE – N RED – L2 120 V BLACK – L1 POWER WALL BLACK – L1 SUPPLY SWITCH (BREAKER GROUND - G GROUND - G PANEL) NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
L1 FROM POWER SUPPLY Insert all the wiring back into the unit and se- cure with a cable clamp. NEUTRAL FROM UNIT AND SUPPLY L1 FROM POWER SUPPLY 2 CONDUCTOR WIRE FROM POWER SUPPLY 2 CONDUCTOR WIRE FROM MAIN SWITCH www.dimplex.com...
120V/240V HEATER WALL SWITCH CONTROL RED – 2 WALL RED – 1 SWITCH GROUND - G NOTE: Before installing the unit complete the following: Install main power connection with appropriate wiring - directly to the main power or through a wall switch. Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit.
Insert all the wiring back into the unit and secure with a cable clamp. BLACK BLACK GROUND BLACK WIRE WHITE WIRE GROUND SCREW GROUND GROUND NOTE: This only illustrates thermostat connection, see previous sections for main power connection instruc- tions. GROUND www.dimplex.com...
120V/240V WALL MOUNTED FLAME OVERRIDE SWITCH BLUE – 4 WALL BLUE – 3 SWITCH GROUND - G DO NOT USE WITH NO HEAT INSTALLATIONS NOTE: The fireplace can be wired to have a wall switch operate the flame independent of the heater. NOTE: Before installing the unit complete the following: Install main power connection with appropriate wiring - directly to the main power or through a wall switch.