    CONTENTS PAGE 1 PAGE 1 PAGE 1 PAGE 2 PAGE 2 PAGE 2 PAGE 3 PAGE 3 PAGE 4 PAGE 5 PAGE 6 - 7 PAGE 8 - 9 PAGE 10 - 11 PAGE 12 - 13 PAGE 14 - 15 PAGE 16 - 18 Listings and Code Approvals Model Specifications...
  • Page 3: Listings And Code Approvals

    LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters. MODEL SPECIFICATIONS Model Description Voltage Volts Number 33” 120/120/208/ BF33ST Standard 120/120/208/ BF33DX...
  • Page 4: Section B

    WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING MODEL BF33ST/DX 15.0” 33.5” BF39ST/DX 16.0” 39.5” BF45ST/DX 16.0” 45.5” Rough-in framing dimensions This fireplace is a zero clearance design.
  • Page 5: Voltage Selector Switch Location

    VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner. CAUTION: When changing the voltage selector switch from 240 volts to 120 volts ensure that the power supply is turned off.
  • Page 6: Section C

    SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit.
  • Page 7: (Without Main Power Wall Switch)

    SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit.
  • Page 8 SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit.
  • Page 9: Section D

    SECTION D: MAIN POWER WALL SWITCH WIRING OPTIONS MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires total) from the power supply panel to the main switch wall box.
  • Page 10 240 VOLT MAIN WALL SWITCH WIRING DIAGRAM WHITE - N WHITE – N 240 V RED – L2 RED – L2 POWER SUPPLY WALL SWITCH BLACK – L1 BLACK – L1 (BREAKER PANEL) GROUND - G GROUND - G...
  • Page 11: Main Power Wall Switch Wiring For 120 Volt

    MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
  • Page 12 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM WHITE - N WHITE – N RED – L2 120 V POWER BLACK – L1 SUPPLY (BREAKER WALL PANEL) BLACK – L1 SWITCH GROUND - G GROUND - G...
  • Page 13 MAIN POWER WALL SWITCH WIRING NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.
  • Page 14 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION WHITE - N WHITE – N RED – L2 120 V POWER Wire Nut BLACK – L1 SUPPLY (BREAKER WALL BLACK – L1 PANEL) SWITCH GROUND - G GROUND - G...
  • Page 15: Section E

    SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit.
  • Page 16 HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) RED – 2 WALL RED – 1 SWITCH GROUND - G...
  • Page 17: Wall Mounted Thermostat Wiring For 120/240 Volt

    WALL MOUNTED THERMOSTAT WIRING NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box on the unit.
  • Page 18: Wiring Diagrams

    WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) CONNECT GROUND TO WALL BOX RED – 2 WALL RED – 1 THERMOSTAT GROUND - G...
  • Page 19: Flame Override Switch Wiring For 120/240 Volt

    FLAME OVERRIDE SWITCH WIRING NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater independent of the flame NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D.
  • Page 20 FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLATION BLUE – 4 WALL BLUE – 3 SWITCH GROUND - G...
  • Page 21: Wiring Diagram

    WIRING DIAGRAM LOWER SECTION BROWN WHITE BLACK BLUE (3) MARR BLACK RED (1) WHITE WHITE (N) BLUE (4) RED (2) BLACK RED (L2)
  • Page 22 WIRING DIAGRAM UPPER SECTION...
  • Page 23 WIRING SCHEMATIC...
  • Page 24 1-888-DIMPLEX 1-888-346-7539 1367 Industrial Road Cambridge, Ontario Canada, N1R 7G8 Approved for use in the United States and Canada...