HANDLING AND MAINTENANCE
Install Log
o
Click the Install log tab to display the list
of applied updates over time.
8.1.4

Recovery

Recovery mode is for trained engineering service personnel. It is a safe mode that allows access to the
E20 on a secondary recovery IP address. The main user settings are still active.
o
You can force the Echotrac E20 echosounder into Recovery mode by pressing the Channel A
and B buttons simultaneously at power up.
o
The Recovery mode will not allow any echosounder operations and the SBES UI will not be
able to see the unit.
o
In this mode it is possible to use the E20 System Tool via the default IP address 10.11.10.1.
o
With the Recovery mode you always have access to a safe working state, which is useful in
e.g. the following circumstances:
There is a loss of power during an E20 software update.
If you have accidentally misconfigured the network settings and cannot get in contact
with the unit.
When resuming normal operation by power cycling the unit, the setup of the SBES is the
same as before (unless modified during the recovery mode session).
8.2

Transducer

7
8.2.1

Handling

o
Use original shipping boxes when shipping or storing the unit.
o
It is important to ensure that the transducer is not dropped or suffers any shock damage.
Avoid impact damage to the unit, as this may damage the internal components.
7
Please, refer to the manufacturer's instructions, as well.