9.2
Specifications – heat pump (three-phase current)
Air/water operation
1)
Power output with A -10/W35
1)
Power output with A -7/W35
, rated output
1)
COP with A -7/W35
, rated output
Modulation range with A -7/W35
1)
Power output with A +2/W35
Modulation range with A +2/W35
1)
Power output with A +7/W35
1)
COP with A +7/W35
, partial load
1)
Power output with A +2/W35
1)
COP with A +2/W35
, partial load
Cooling capacity with A 35/W7
1)
EER with A 35/W7
Cooling capacity with A 35/W18
1)
EER with A 35/W18
Electrical details
Power supply
Protection index
Fuse rating for supplying the heat pump directly via the building
2)
connection
Maximum power consumption
Performance factor cos phi with maximum output
Rated power input of compressor with A -7/W35 rated output
Performance factor cos phi with A7/W35
Heat pump soft start
Soft start type
Max. number of compressor starts
Starting current
Heat transfer medium
Minimum flow
Internal pressure reduction
Air and noise generation
Max. fan motor output (DC transformer)
Maximum air current
Sound pressure level at a distance of 1 m, 35% compressor speed
3)
Sound power
Max. sound power
Max. sound power "quiet operation"
General details
4)
Refrigerant
Refrigerant charge
CO
(e)
2
Maximum temperature of flow, heat pump only
Installation altitude above sea level
Dimensions (W x H x D)
Weight without walls and top cover
Weight with walls and top cover
1) Performance data in accordance with EN 14511
2) Fuse class gL/C
3) Sound power level in accordance with EN 12102
4) GWP100 = 2088
Table 19 Specifications – heat pump (three-phase current)
Compress 7001i AW – 6721835318 (2021/09)
, 100% compressor speed
1)
, 100% compressor speed
1)
, partial load
, partial load
1)
1)
Unit
13 OR-T
KW
9.97
KW
10.73
2.74
4.0-10.7
KW
11.71
5-12
KW
5.18
5.00
KW
7.00
3.64
KW
8.86
2.72
KW
11.12
3.23
400V 3N AC, 50Hz
IP X4
A
13
KW
7.2
>0.97
KW
3.92
>0.97
Yes
Inverter
1/h
10
<5
l/s
0.62
kPa
15.8
W
280
m³/h
7300
dB(A)
45
dB(A)
53
dB(A)
64
dB(A)
57
R410A
kg
3.3
Tonne
6.89
°C
62
Up to 2000 m above sea level
mm
1122x1695x545
kg
154
kg
182
Technical information
17 OR-T
12.30
13.02
2.55
4.0-13.0
14.37
5.5-14
5.63
4.87
7.86
4.04
9.69
2.68
11.45
3.77
400V 3N AC, 50Hz
IP X4
13
7.2
>0.97
5.11
>0.97
Yes
Inverter
10
<5
0.81
22.9
280
7300
45
53
64
58
R410A
4.0
8.35
62
1122x1695x545
165
193
23