DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
17. Install the four nuts
that hold in place the
compressor to the
base rails using a
7/16" socket ratchet.
Instructions to Replace Compressor.
18. Proceed to braze the
service, discharge and
suction tubing.
19. Braze the filter to the condenser
discharge line and to the capillary
tubing.
Do not over heat the body of the filter
and take great care not to block the
capillary tubes with solder material.
The filter dryer must be installed in a
vertical position with the capillary
tube inlet at the bottom of the filter.
20. Please review the
slides 19 through 23 to
install the relay, overload
protector and starting
capacitor.