DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instruction to Replace Starting Relay, Overload Protector and Starting Capacitor.
1. Unscrew the four screws
that hold in place the
front grill , using a
Phillips screwdriver # 2
2. Pull out the front grill.
3. Disconnect the Tyco
electrical connector of
the condensing unit.
4. Remove the two bolts
that hold in place the
rails using a 1/2" open
wrench, these rails
support the condensing
unit.