DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
9. Pull out the condenser
fan.
Instructions to Replace Condenser Fan Motor
10. Remove the bolt that hold
in place the fan blade to
the fan motor using a
9/32" socket screwdriver.
11. Unscrew. the two
screws that hold in
place the base motor
to the fan motor using
a 9/32" socket
screwdriver.
12. To install the new
condenser fan motor
reverse the previous
steps.