Components
Single surface units:
Left Rear(LR)
Right Rear(RR)
Element
Test procedures
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate 47 Ω ± 10%
2A
5. Touch the ohmmeter test leads to limiter terminals
1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0Ω).
1B
2B
1A
4-5
Results
Normal: Approximately 47 Ω,
If not replace
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0 Ω)