Components
Broil heater
Lower oven
Conv. heater
Test procedures
1. Remove wire leads
2. Measure resistance after cooling down
1. Remove wire leads
2. Measure resistance after cooling down
4-4
Results
Normal : Approximately 14.7 Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77˚F/25˚C)
Be careful the element is
sensitive to temperature.
Normal : Approximately 24 Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was tested
at room temperature
(77˚F/25˚C)
Be careful the element is
sensitive to temperature.