Troubleshooting The Basic I/O Functions - Dell 4100 Installation And Troubleshooting Manual

Dell poweredge 4100 servers: install guide
Hide thumbs Also See for 4100:
Table of Contents

Advertisement

A faulty cable between the I/O port and the periph-
eral device
A faulty peripheral device
Incorrect settings in the System Setup program
Incorrect settings in the system's configuration files
Faulty I/O port logic on the system board
NOTE: With certain modems installed, subtests in the
Serial Port Test Group may fail because the modem
appears to the diagnostics as a serial port, but it cannot
be tested as a serial port. If you have a modem installed
and you experience a serial-port test failure, remove the
modem and run the diagnostic tests again.
Troubleshooting the Basic I/O
Functions
This procedure determines whether the computer's basic
I/O functions are operational. If a system error message
indicates an I/O port problem or the device connected to
the port does not function properly, follow these steps:
1.
Enter the System Setup program, and check the
settings for the
SERIAL PORT
, and
PARALLEL PORT
Are the communications port categories set to
and is the
category set to
MOUSE
Yes. Go to step 3.
No. Go to step 2.
2.
Change the setting for the
, and
2
PORT
PARALLEL PORT
and change the setting for the
; then reboot the system.
ENABLED
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 3.
,
1
SERIAL PORT
categories.
MOUSE
AUTO
?
ENABLED
,
1
SERIAL PORT
SERIAL
categories to
AUTO
category to
MOUSE
3.
Check the contents of the start-up files.
See "Installing and Configuring Software" in Chap-
ter 4.
Are the port configuration commands correct?
Yes. Go to step 5.
No. Go to step 4.
4.
Change the necessary statements in the start-up
files.
If the port problem is confined to a particular appli-
cation program, see the application program's
documentation for specific port configuration
requirements.
Is the problem resolved?
Yes. You have fixed the problem.
No. Go to step 5.
5.
Reboot the system from the Dell Server Assistant
CD, and run the Serial Port Test Group and/or
the Parallel Port Test Group in the system
diagnostics.
,
2
See Chapter 5, "Running the System Diagnostics."
The Serial Port Test Group and the Parallel Port Test
,
Group test the basic functions of the system board's
I/O port logic. Also, if a parallel printer is connected
to the parallel port, the Parallel Port Test Group tests
the communications link between the system board's
I/O port logic and the printer.
Do the tests complete successfully?
,
Yes. Go to step 6.
No. See Chapter 11, "Getting Help," for instructions
on obtaining technical assistance.
6.
If the problem persists, go to "Troubleshooting a
Parallel Printer" or "Troubleshooting a Serial
I/O Device" found later in this chapter, depending
on which device appears to be malfunctioning.
Checking the Equipment
6-3