4.
Replace the computer cover, reconnect the com-
puter to its power source, and turn it on.
The existing passwords are not disabled (erased)
until the system boots with the PSWD jumper plug
removed. However, before you assign a new system and/or
user password, you must install the jumper plug.
NOTE: If you assign a new system and/or user pass-
word with the jumper plug still removed, the system
disables the new password(s) the next time it boots.
5.
Repeat step 1.
6.
Install the jumper plug on the PSWD jumper.
7.
Replace the computer cover, reconnect the com-
puter and peripherals to their power sources, and
turn them on.
8.
Have the user assign a new system and/or user
password.
To assign a new supervisor password using the Sys-
tem Setup program, see "Assigning a Supervisor
Password" in Chapter 4 of the system User's Guide.
To assign a new supervisor password using the EISA
Configuration Utility, see "Assigning or Changing a
Supervisor Password" in Chapter 5 of the system
User's Guide.
To assign a new user password using the System
Setup program, see "Assigning a User Password" in
Chapter 4 of the system User's Guide. To assign a new
user password using the EISA Configuration Utility,
see "Assigning or Changing a User Password" in
Chapter 5 of the system User's Guide.
C-6
Dell PowerEdge 4100/180 and 4100/200 Systems Installation and Troubleshooting Guide