Cable Glands For Small Hulls - Simrad ES38-7 Installation Manual

Split-beam transducer
Hide thumbs Also See for ES38-7:
Table of Contents

Advertisement

Cable glands for small hulls

For smaller vessels that do not need to be classified, a different cable gland can be used.
Packing nipple
A
B
Rubber gaskets
Plastic disc
C
Rubber gaskets
D
Bushing
E
Backing nut
F
Backing washer
G
O-ring
H
O-ring
I
Cable to echo sounder (or a
J
junction box)
Note
Make sure that you do not damage the
transducer cable by tightening the packing nipple too hard.
The O-ring must be clean, in good condition and free of cuts or other defects which could
affect their watertight integrity.
Apply ample amount of sealant between the backing washer (H) and the hull plate.
Note
Kongsberg Maritime takes no responsibility for the correct manufacturing, installation
of cable glands, associated hull modifications and/or structural support of transducer
cable penetration. These activities are subject to individual approval by the respective
classification society for the vessel in question.
Related topics
Transducer installation principles, page 45
404292/D
Transducer installation principles
57