14.2 Indoor Fan Motor Operation
14.2.1
Basic Rotation Speed (rpm)
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry, Fan]
Fan motor's number of rotation is determined according to remote control setting.
[Heating]
Fan motor's number of rotation is determined according to remote control setting.
ii Auto Fan Speed
[Cooling, Dry]
According to room temperature and setting temperature, indoor fan speed is determined automatically.
When set temperature is not achieved, the indoor fan will operate according to pattern below.
Fan
Speed
a
b
Higher
Medium
Lower
When set temperature achieved, the indoor fan speed will be fixed. When thermostat off, the fan stop periodically.
[Heating]
According to indoor pipe temperature, automatic heating fan speed is determined as follows.
B. Feedback control
Immediately after the fan motor started, feedback control is performed once every second.
During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan
motor error is detected. Operation stops and cannot on back.
Remote control
○
Tab
Hi
Remote control
○
Tab
SHi
c
d
e
o
39
C
o
19
C
Indoor Pipe Temp.
○
○
Me+
Me
○
○
Me+
Me
[1 pattern : 10 s]
f
g
h
RPM Increased
RPM Maintain
o
35
C
RPM Reduced
o
16
C
OFF
95
○
○
Me-
Lo
○
○
Me-
Lo
a
b