14.1.5
Automatic Operation
This mode can be set using remote control and the operation is decided by remote control setting temperature,
remote control operation mode and indoor intake air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the
indoor intake air temperature.
Every 10 minutes, the indoor temperature is judged.
For the 1st judgment
If indoor intake temperature - remote control setting temperature ≥ 2°C, COOL mode is decided.
o
If -2°C ≤ indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
o
For the 2nd judgment onwards
If indoor intake temperature - remote control setting temperature ≥ 3°C, if previous operate in DRY mode,
o
then continue in DRY mode. Otherwise COOL mode is decided.
If -2°C ≤ indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
o
14.1.6
iAUTO-X Operation
iAUTO-X operation can be set using remote control.
This operation is applied to faster cool down time of the room and comfort feel by thermal shift and fan speed
control.
Thermal control
The internal setting temperature will shift 1°C lower than remote control setting temperature for maximum 4
o
hours to provide extra cool and better comfort.
After max. 4 hours, the remote control setting temperature will shift according to activity detection as below;
o
Fan speed control
Fan speed selection is prohibited. Fan speed display at remote control is fixed at AUTO.
o
The internal fan speed will set to be SHi + iAUTO-X fan speed shift, it is slightly higher than SHi fan speed
o
initially for maximum 30 minutes to achieve the setting temperature quickly. Then it will shift between SHi ~
Lo fan speed depends on intake and setting temperature.
Vane control is follow remote control setting. Except for Auto horizontal vane, when room temperature more than
27°C, it will give a spot airflow (inner and outer vanes will be in a smaller distance). When room temperature cool
down, it will either fixed at step 3 or step 1 (Showering effect for better comfort after room temperature cooled
down) depends on the "intake - setting temperature".
14.1.7
Fan Operation
Fan operation is used to circulate air in the room.
During operation, indoor fan run continuously but outdoor fan and compressor stop.
Temperature setting is not applicable.
Heat
-6
-5
-4
-3
-2
Heat
-6
-5
-4
-3
-2
i AUTO-X ; Fast cooling to maximum of 4 hours, the unit continue to provide cooling comfort according human
presence and activity detection.
Human
Mode
Set
i AUTO-X
temperature
Dry
Cool
-1
0
1
2
3
4
Maintain
current mode
-1
0
1
2
3
4
Low activity
Normal activity
+1 °C
94
5
6
Cool
/Dry
5
6
High activity
Absent
+2 °C
-1 °C