Failure to read these warnings may cause the unit to fail, personal injury or property
damage.
 Equipment should only be operated on a single phase, 120VAC, 15 Amp grounded
electrical system. The plug is a Hubbell #5266C. A Hubbell #5261, or compatible,
receptacle is required.
 Do not plug equipment into a power source that utilizes a GFI receptacle. Ultrasound
passes a small, trickle current through the neutral which will cause GFI's to trip.
 Never plug in or operate the unit (heat or ultrasound) without the appropriate liquid
level in the tank (2/3 full).
 Any detergents or chemicals used in this equipment must be compatible with 300
series stainless steel. Do not use any chemicals that contain any strong acids i.e.
hydrochloric, sulfuric or muriatic acid. These chemicals will cause permanent
damage to the stainless steel welds.
 Due to the heated liquid in the tank, use baskets, tongs or wires to insert or remove
parts from the tank.
 Do not operate the unit with wet hands.
 Use only biodegradable cleaning agents. Never use solvents or flammable cleaning
solvents without approval from Omegasonics. Any chemistry with a flash point below
180˚F should never be used with an ultrasonic cleaner.
 Do not rest parts to be cleaned directly on the radiating surface. The custom
Omegasonics 1420 basket, which suspends the basket bottom above the tank, must
be used.
 Do not open the internal circuitry of the equipment, disassemble any part or parts, or
move or remove any components or electrical devices.
 Never attempt to perform maintenance on the equipment when the unit is energized
or when the cleaning solution is hot.
 Disconnect the power source when moving the unit to a new location.
 Avoid splashing water outside the tank.
Only qualified technically trained personnel should perform any electrical maintenance on this machine.