Removal of Electrical Parts
1. Control box
a) Remove the service panel from the logo side panel. (See step 3 on page 22)
b) Remove the following number of screws and remove each electrical part from the control
box.
- Communication module: two (2) screws
- Terminal block 1: two (2) screws
- Terminal block 2: two (2) screws
- Compressor motor capacitor: one (1) screw
- Drain switch: two (2) screws
Communication Module
Relay Board
Screw (2)
Terminal Block 2
(For Input/ Output Signal)
Capacitor for Compressor
28
Screw (2)
Screw (1)
Screw (2)
Terminal Block 1
(For Power)
Drain Switch
Screw (2)