USING THE UNIT

Operation is simple, just keep it connected to the correct
power supply and the refrigerator will maintain the
internal temperature it has been set to. Keep the doors
closed as much as possible to avoid unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
The temperature was set at the factory at 38
you can adjust it to your own selected temperature. 30
seconds after adjustment, the display automatically
reverts to showing the current temperature. The
compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point
Defrost
Select
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed
Hi
dOr
LEA
E01, E02, E03, E04
Rev. 06/20
F, but
º
38.0
Why
Cabinet temperature too warm
Door is open
Compressor run time too long
Sensor unplugged or has failed
Beverage-Air
Beverage-Air
F
o
What to do
Confirm doors or drawers are closed.
Close door, if message does not
change, call for service.
Check doors closed. If yes, call for
service.
Call for service.