Beverage-Air UCR Series Installation And Operating Instructions Manual

Beverage-Air UCR Series Installation And Operating Instructions Manual

Hydrocarbon refrigerators

Advertisement

INSTALLATION AND OPERATING INSTRUCTIONS
for all Hydrocarbon
UCR Refrigerators
809-173A 7/10/2020
SEE BACK COVER FOR
3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
WARRANTY REGISTRATION
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com

Advertisement

Table of Contents
loading

Summary of Contents for Beverage-Air UCR Series

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon UCR Refrigerators 809-173A 7/10/2020 SEE BACK COVER FOR 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 WARRANTY REGISTRATION Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com...
  • Page 2: Table Of Contents

    If you meets the high standards set by Beverage-Air! You have have any questions, Please call our Technical Service made a quality investment that with proper maintenance Department at (800) 684-1195.
  • Page 3: Safety

    R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
  • Page 4: Important Information

    User Manual for UCR Refrigerators Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site.
  • Page 5: Product Information

    User Manual for UCR Refrigerators Beverage-Air PRODUCT INFORMATION Power Refrigerant Type Cabinet Dimensions Door or Drawer Full Load Model Door Type Cord Plug / Charge g / w x d x h (Inches) Count Amps (NEMA) Charge oz UCR20HC 20 x 24 1/2 x 31 1/8...
  • Page 6: Clearance And Placement

    User Manual for UCR Refrigerators Beverage-Air CLEARANCE AND PLACEMENT 0" MINIMUM CLEARANCE 0" 3" 2" LEFT/RIGHT SIDE BOTTOM REAR MINIMUM MINIMUM MINIMUM CLEARANCE CLAERANCE CLEARANCE Placement Consider the following when selecting a location for your Refrigerator: Clearance: • - Top •...
  • Page 7: Unpacking And Set Up

    User Manual for UCR Refrigerators Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
  • Page 8: Electrical

    User Manual for UCR Refrigerators Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
  • Page 9: Using The Unit

    User Manual for UCR Refrigerators Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct power supply and the refrigerator will maintain the internal temperature it has been set to. Keep the doors closed as much as possible to avoid unnecessary run time.
  • Page 10: Sequence Of Operations Refrigerator

    User Manual for UCR Refrigerators Beverage-Air SEQUENCE OF OPERATIONS REFRIGERATOR The refrigerator operates based on the air temperature measured by the probe located at the return air. COMPONENT OPERATION CONTROLLER ACTION OPERATION CONTROLLER ACTION Compressor turns The Compressor The Compressor...
  • Page 11 User Manual for UCR Refrigerators Beverage-Air DEFROST (ESC) Electronic Controller SELECT (OK) DOWN Control Panel Display Note: Defrost is manual, LED indicator is inoperative. Defrost LED Alarm LED On fixed: Defrost active On fixed: ALARM Present Off: Defrost is off...
  • Page 12 User Manual for UCR Refrigerators Beverage-Air Control Panel Connections Changing the Set point Beverage-Air Rev. 06/20...
  • Page 13 User Manual for UCR Refrigerators Beverage-Air Electronic Controller Alarms Alarm Trigger Automatic Outputs Comments Code Clearance "Hi" Air temperature is higher than User Bl ink "Hi" with the highest temperature; If High temperature "ALA->Hat• for "ALA->Htd" configured configured: cut in alarm relay, beep the buzzer alarm "Lo"...
  • Page 14: Cleaning And Maintenance

    User Manual for UCR Refrigerators Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection Annually Weekly interior Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.
  • Page 15: Condenser Cleaning

    User Manual for UCR Refrigerators Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient the unit. operation. 6. To reinstall the rear panel line up the bottom of the The condenser coil is located right behind the back grille panel to the bottom of the unit keeping the screw of the cabinet.
  • Page 16: Methods For Cleaning Stainless Steel

    User Manual for UCR Refrigerators Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless...
  • Page 17: Help

    User Manual for UCR Refrigerators Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
  • Page 18: For The Service Tech - R290

    User Manual for UCR Refrigerators Beverage-Air FOR THE SERVICE TECH - R290 Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a Evacuation: It is critical that a refrigeration system be reminder and checklist for the service tech.
  • Page 19: For The Service Tech - Wiring Diagram

    User Manual for UCR Refrigerators Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM CNTRL *SEE CONTROLLER DETAIL CONDENSER FAN CURRENT RELAY COMP *SEE CONTROLLER DETAIL COMPRESSOR DETAIL (115V 1PH) EVAP FANS POWER *SEE CONTROLLER DETAIL SUPPLY *NOT ALL MODELS* LAMP L.E.D.
  • Page 20: Limited Warranty

    (87) months from the date of defective. shipment from Beverage-Air, provided upon receipt of the The labor warranty shall be for self-contained units compressor, manufacturer examination shows the sealed only and for standard straight time, which is defined as compressor to be defective.
  • Page 21: Limited Warranty (Continued)

    With the exception of Blast Chillers product is designed for LIMITATION OF LIABILITY: maintaining temperature and not bringing food to a desired Beverage-Air Corporation or their affiliates shall not be temperature therefore cannot be held responsible for this liable for any indirect, incidental, special or consequential function under warranty.
  • Page 22 User Manual for UCR Refrigerators Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...

Table of Contents