Beverage-Air VM12 Installation And Operation Manual

Beverage-Air VM12 Installation And Operation Manual

Beverage-air refrigerator user manual

Advertisement

Beverage Air
3779 Champion Blvd
Winston-Salem, NC 27105

INSTALLATION AND OPERATION

MANUAL
VM2, VM7, VM12, VM18
Congratulations! You have just purchased the finest commercial
refrigeration available.
•••• www.beverage-air.com ••••

Advertisement

Table of Contents
loading

Summary of Contents for Beverage-Air VM12

  • Page 1: Installation And Operation Manual

    Beverage Air 3779 Champion Blvd Winston-Salem, NC 27105 INSTALLATION AND OPERATION MANUAL VM2, VM7, VM12, VM18 Congratulations! You have just purchased the finest commercial refrigeration available. •••• www.beverage-air.com ••••...
  • Page 2: Table Of Contents

     We strongly recommend servicing be performed by a qualified individual. •••• www.beverage-air.com • Pg. 2 •••• WARNING!  Do not allow children to climb, stand, or hang on the shelves in the refrigerator. They could damage the refrigerator and seriously injure themselves.
  • Page 3: Application

    The unit is constructed to facilitate using a forklift to handle it. (Fig. 1) Use this handling means to move the equipment as close as possible to the location where it will be installed. IMPORTANT: Never push, pull or strike the front or side glass. Figure 1 •••• www.beverage-air.com • Pg. 3 ••••...
  • Page 4: Placing And Installing The Equipment

    The unit should be leveled prior to operation. Figure 3 The unit must have casters, 6” legs, or sealed to the floor per NSF guidelines as shown in Figure 4A and •••• www.beverage-air.com • Pg. 4 ••••...
  • Page 5: Electrical Requirements

    PRODUCT LOADING The VM series of units are not intended to be a pull down refrigerator and as such the product must be loaded at their intended merchandising temperature.
  • Page 6: Unit Operation And Components

    The control has been factory-adjusted with a defrosting cycle scheduled to last 6 minutes every hour to ensure that the evaporator performs without any ice build-up. None of the factory-programmed electronic control parameters can be modified unless an access code is entered (only your distributor's technical personnel have that code). •••• www.beverage-air.com • Pg. 6 ••••...
  • Page 7 COMPRESSORS: The VM2, and VM7 has a single hermetic compressor. The VM12 and VM18 each have two hermetic compressors that start in two steps with a delay of 10 seconds to reduce the in-rush of current to the unit. CONDENSERS: The VM 7, 12, and 18 units incorporate a "maintenance free"...
  • Page 8: Prescriptions, Prohibitions And Other Uses For The Equipment

    VM2: 20 kg (44 Lbs) VM7, VM12: 50 kg (110 Lbs). VM18: 60 kg (132 Lbs) This load limits must not be exceeded to prevent potential damage to the shelf and/or injury to users.
  • Page 9: Maintenance Guidelines

    4. Replace the grill assembly. 5. Connect power to the unit and verify that when required the condensing unit(s) are running. If you cannot remove the dirt adequately, please call your refrigeration service company. •••• www.beverage-air.com • Pg. 9 •••• FIGURE 10...
  • Page 10 If replacing parts is required, do it through your distributor. WARNING: Always ask for original spare parts AUTHORIZED DISTRIBUTOR: _____________________________________ COMMERCIAL NAME: _____________________________________ ADDRESS: _____________________________________ TELEPHONE: _____________________________________ E-MAIL: _____________________________________ •••• www.beverage-air.com • Pg. 10 •••• TECHNICAL ASSISTANCE...