Please call our Technical Service meets the high standards set by Beverage-Air! You have Department at (800) 684-1199. 8:00 AM to 5:00 PM EST. made a quality investment that with proper maintenance...
R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store or use gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
Page 4
User Manual for VM Refrigerators Beverage-Air Using any electrical or electronic equipment entails the compliance with some fundamental rules. 1. Do not touch the unit with wet hands or feet. 10. Use care when moving or handling the unit. It is equipped with flammable refrigerant and damage to 2.
Page 5
User Manual for VM Refrigerators Beverage-Air CAUTION: If it is necessary to move the Refrigerator after removal from the skid, CAUTION remove all doors and carefully push the unit at a point of no more than 36” from the bottom to avoid damage.
User Manual for VM Refrigerators Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site.
User Manual for VM Refrigerators Beverage-Air PRODUCT INFORMATION Cabinet Dimensions Full Load Power Cord Refrigerant Type / Charge (g) Model w x d x h (Inches) Amps Plug (NEMA) / Charge (oz) VMHC-7-1 35 7/16 X 31 3/4 X 63 25/32 5-15P R-290 / 126 / 4.25...
User Manual for VM Refrigerators Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
User Manual for VM Refrigerators Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
User Manual for VM Refrigerators Beverage-Air ENVIRONMENTAL CONDITIONS The location of the cooler must be kept away from sources of THIS UNIT CANNOT BE INSTALLED IN ENVIRONMENTS WITH EXPLOSIVE GASES, IT IS DESIGNED ONLY FOR heat and humidity including direct sunlight, ovens, heaters, INDOOR OPERATION.
User Manual for VM Refrigerators Beverage-Air POSITIONING THE SHELVES AND LOADING THE UNIT POSITIONING THE SHELVES To prevent potential damage to the unit and/or injury, never exceed the shelf weight limits in the table below The shelves and holders have been fixed to the inside floor of the unit to prevent their loss during transportation.
User Manual for VM Refrigerators Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check Annually that hinges are tight to Weekly interior the cabinet. Regularly and carefully cleaning the equipment prevents deterioration and product alteration. It is much easier to clean on a regular basis than to have to remove stains once they have built up.
User Manual for VM Refrigerators Beverage-Air METHODS FOR CLEANING Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless on the package.
User Manual for VM Refrigerators Beverage-Air CLEARING THE DRAIN LINES ÿ ÿ !" # $ ÿ & ' (# ÿ It is likely that over time the drain lines will become clogged, which will result in water overflowing the 67 8 9 7 ÿ...
User Manual for VM Refrigerators Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
User Manual for VM Refrigerators Beverage-Air FOR THE SERVICE TECH - R290 Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Mechanical Components: • The units will have either one or two compressors This list does not qualify anyone to service the unit.
Our obligation under this warranty shall be limited to to exceed eighty-seven (87) months from the date of repairing or replacing, including labor, any part of such shipment from Beverage-Air, provided upon receipt of the product, which proves thus defective. Beverage-Air compressor, manufacturer examination shows the sealed reserves the right to examine any product claimed to be compressor to be defective.
With the exception of Blast Chillers, the product is designed LIMITATION OF LIABILITY: for maintaining temperature and not bringing food to a Beverage-Air Corporation or their affiliates shall not be desired temperature therefore cannot be held responsible liable for any indirect, incidental, special or consequential for this function under warranty.
Page 23
User Manual for VM Refrigerators Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...
Need help?
Do you have a question about the VMHC-12-1 Series and is the answer not in the manual?
Questions and answers