User Manual for BB Refrigerators
Alarm
Trigger
Code
"Hi"
Air temperature is higher than
"ALA->Hat• for "ALA->Htd"
"Lo"
Air temperature is lower than
"LAt" for "Ltd''
"Con"
Condenser temperature is too
high or too low
"dor"
Door open for more than
"uHi"
Line voltage is higher than "Cop-
>uHi"
"uLi"
Line voltage is higher than "Cop-
>uLi"
"LEA"
Compressor cont inuous running
for more than "ALA->LEA"
"E01"
"S1" error
"E02"
"S1" error
"E03"
"S1" error
"E04"
"S1" error
How to Acknowledge Alarms
Rev. 06/20
Automatic
Outputs
Clearance
User
Bl ink "Hi" with the highest temperature; If
configured
configured: cut in alarm relay, beep the buzzer
User
Blink "Lo" with the lowest temperatu re. If
configured
configured: cut in alarm relay, beep the buzzer
User
Blink "Con". If configured: cut in alarm relay, beep the
configured
buzzer
Always
Blink "dor". If configured: cut in alarm relay, beep the
buzzer
Always
Blink "uHi". If configu red: cut in alarm relay, beep the
buzzer
Always
Blink "ulo". If configured: cut in alarm relay, beep the
buzzer.
Always
Blink "LEA". If configured: cut in alarm relay, beep the
buzzer
Always
Blink "SOl ". lf configured: cut in alarm relay, beep the
buzzer
Always
Blink "SO2". lf configured: cut in alarm relay, beep the
buzzer
Always
Blink "S03 ". lf configured: cut in alarm relay, beep
the buzzer
Always
Blink "SO4 ". lf configured: cut in alarm relay, beep
the buzzer
Beverage-Air
Beverage-Air
Comments
High temperature
alarm
Low temperature
alarm
Condenser alarm
Door open alarm
High voltage alarm
Low voltage alarm
Leakage alarm
"S1" sensor failure
(short or open)
"S2" sensor failure
(short or open)
"S3" sensor failure
(short or open)
"S4" sensor failure
(short or open)