PRODUCT SANDOR Product code SANDOR QUAD ESA SMA SANDOR QUAD - ESA DOUBLE OPTIC PERIMETER BARRIER INSTALLATION AND MOUNTING MANUAL VERSION 3.1...
The system has been designed to detect intrusions and activate the alarm; it is not a device that prevents intrusion.Politec is not responsible for damage, injury or loss caused by accidents, theft, force majeure (including momentary lightning-induced overcurrent), abuse, improper or incorrect use, faulty installation or inadequate maintenance.
• Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation; lack of maintenance, incorrect assembly or use. • Politec is also not liable for incorrect or incomplete operation of the product or failure to detect intrusion. •...
The package contains the following components and accessories. When opening the package, check that everything has been included. COMPONENT Aluminium profile Caps Transmitter\Receiver optics QUAD B RX / TX motherboard Black polycarbonate cover SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
• Check that the surface chosen for the installation of the product is sturdy so as to ensure stable fixing and that it is adequately protected against possible impacts or the elements. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
Pole mounting Wall mounting with Wall mounting with with SAN/PL SAN/SD brackets SAN/PL pole brackets brackets (recommended protection of sections along the wall) SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
WARNING: Product warranty is invalid if there is any hole in the aluminium profile or any component SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
TX and RX, thereby ensuring a good amount of signal constantly, even in case of particular climatic conditions. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
DO NOT place barriers close to roads: vehicle lights directed towards the RX could create disturbances DO NOT place barriers near automatic gates: photocell signals can create interference. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
9.Installation examples 9.1 Barrier positioning In addition to standard products, all Politec products can be customised according to the installation needs including height of the columns, number of beams inside and the different ways they are arranged. This barrier, always composed of a TX column and an RX column, lends itself well to single barrier systems and for the protection of facades, as well as in the open field, observing the necessary precautions, given by their characteristics (e.g.
The sizing of the cables depends on the consumption of the columns and on the resistance of the cable itself according to the distances involved. The table shows the cable cross-sections and the relative distances to ensure optimum performance using the LAR22 power supply (12Vdc-2.5A/24Vac-300W) and a SANDOR QUAD ESA SMA column (4TX or 4RX). CONDUCTOR CROSS-...
It is sufficient to apply the filter only on the TX, there is no need to repeat the operation also on the SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
The maximum alignment condition will be reached when the high-intensity LEDs are on steady and the buzzer will emit a continuous sound, for this reason, it may be necessary to make minor adjustments also on the RX optic. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
Page 18
TRANSMITTER optic with your hand: if the RECEIVER continues to give a continuous beep, it means that it sees another infrared source that must be turned off and eliminated. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
AM - Lit if receiving IR interference 5 DIP SWITCH UNIT 10 DIP SWITCH UNIT FOR CONFIGURATIONS FOR BEAM SELECTION • AND RANDOM: DIP 2 SEE SPECIFICATIONS IN • DISQUALIFICATION: CHAP 15.3 DIP 3 SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
By adjusting the potentiometer clockwise, the intervention time decreases up to 50ms. In this condition, an alarm is guaranteed for a person crossing the barrier running at maximum speed. ALARM SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
HEATERS LED Yellow TRIMMER Intervention time adjustment 10 DIP SWITCH UNIT Channel and beam selector 5 DIP SWITCH UNIT Function selector SW4 JUMPER Heater power supply switch TAMPER Column tamper connection SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
HTR LED guarantee an internal temperature between 17°C and LED confirming that the heating 22°C under all climatic conditions. system is on Normally off, when on the heating is active. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
In ON the cross beam function is activated. In ON the "ANTIMASK" and IR filter function is activated.The condition information can be transferred from the output of the dedicated terminal. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
SW4 Heater power supply switch POWER SUPPLY LED Green HEATERS LED Yellow 10 DIP SWITCH UNIT Channel and beam selector SW4 JUMPER Heater power supply switch TAMPER Column tamper connection SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
In ON it disables all the transmitters.It is a useful function for checking TX OFF the presence of external IR interference during the alignment phases In ON the LED indicator on the board is turned on. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
(SW4) on all optics and on the QUAD B TX board. The voltage can be both AC and DC. N.B.:The settings relating to the addressing are already set by default. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
N.B.:The settings relating to the addressing are already set by default. N.B.:The barrier can result in an alarm even if the WEAK SIGNAL LED is off.The cause may be the lack of synchronism or a misaligned transmitter. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
Total beams 4TX + 4RX 6TX + 6RX Power supply 12-24Vdc 12-24Vdc Consumption per 120 mA 135 mA pair Column internal 50W 24Vac 70W 24Vac heaters with thermostat with thermostat SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...
For more precise alignment, position one side of the column cover in front of the lenses in order to have two surfaces interposed between TX and RX to double the attenuation of the beam. SANDOR QUAD ESA POLITEC | INSTALLATION MANUAL - VER.3.1...
Page 31
If the system uses a switching power supply, replace it with a linear one to avoid electrical disturbances coming from the network, we recommend the LAR22 power supply; If possible, increase the intervention time. SANDOR QUAD ESA SMA POLITEC | INSTALLATION MANUAL - VER.3.1...