Download Print this page
Felton AXISS FUSION PLUS AXFSPCSMB Installation Manual

Felton AXISS FUSION PLUS AXFSPCSMB Installation Manual

Shower mixer black

Advertisement

Quick Links

INSTALLATION GUIDE
AXISS FUSION PLUS® SHOWER MIXER BLACK AXFSPCSMB
SYSTEM REQUIREMENTS
Unequal Pressure - Venturi jet installed
Operating Pressures - refer to the Venturi Selection Table on page 2
Equal High (Mains) & Equal Low Pressures - Venturi jet removed
Operating Pressures
Operating Hot Water Temperatures
Operating Cold Water Temperatures
Do not plug outlet when testing.
This shower mixer can be line tested up 1500kPa (217.6psi)
AS/NZS 3500.1 states that pressures above 500kPa can cause damage from water hammer, reduce the life of
appliances, taps & fittings, cause excessive noise in the system and recommend that a pressure limiting valve (PLV) be fitted.
WHAT IS IN THE PACK
Faceplate + O-Ring
Handle
IMPORTANT:
Factory fitted WITHOUT
Venturi Jet
BEFORE INSTALLATION
Pipework MUST be purged before connecting to the mixer
MIXER ORIENTATION
This mixer is designed to be connected with the hot water
supply on the left only and the cold water supply on the
right only.
If at any point the nut is removed, please ensure that both
black lines marked on the cartridge and cartridge nut are
aligned when the mixer is in full cold position as shown in
figure 1.
Patented New Zealand No. 605175
Mixer Assembly
MINIMUM
Hot
36kPa (5.1psi)
200kPa (29.0psi)
36kPa (5.1psi)
55° C
5° C
2x Venturi Jets for Unequal Pressures
Red
O-ring
TOP VIEW
Round Top
Grub Screw
Handle Cap
OUTLET
HOT
INLET
ONLY
MAXIMUM
Cold
1500kPa (217.6psi)
1500kPa (217.6psi)
60° C
N/A
Black
O-ring
TOP VIEW
Hex Top
8g x 32 Dome Head
Square Drive
Stainless Steel Screws
2.5mm Allen Key
COLD
INLET
ONLY
( FULL COLD POSITION )
Figure 1.
Page 1

Advertisement

loading

Summary of Contents for Felton AXISS FUSION PLUS AXFSPCSMB

  • Page 1 INSTALLATION GUIDE AXISS FUSION PLUS® SHOWER MIXER BLACK AXFSPCSMB SYSTEM REQUIREMENTS MINIMUM MAXIMUM Cold Unequal Pressure - Venturi jet installed 1500kPa (217.6psi) Operating Pressures - refer to the Venturi Selection Table on page 2 36kPa (5.1psi) 200kPa (29.0psi) Equal High (Mains) & Equal Low Pressures - Venturi jet removed 36kPa (5.1psi) 1500kPa (217.6psi) Operating Pressures...
  • Page 2 IF YOU HAVE... EQUAL LOW PRESSURE OR EQUAL HIGH/MAINS PRESSURE Install product as supplied. UNEQUAL PRESSURE Follow this guide to select the correct Venturi Jet for the pressure situation: Black O-ring O-ring ROUND TOP HEX TOP Venturi Jet (small hole) Venturi Jet (large hole) Recommended for 36kPa Recommended for 76kPa or...
  • Page 3: How To Install

    Warranty, Maintenance and Care YOUR COPY TO KEEP Felton Industries Limited guarantees these mixers to be free from defects in materials and workmanship for a period of ten (10) years from the date of purchase. Fair wear and tear is expressly excluded.
  • Page 4 TROUBLESHOOTING - SWAPPING OUT THE VENTURI JETS Remove the handle and disassemble the mixer: Remove the insert disc using long nose pliers by carefully inserting the nose of the pliers into the indicated areas A & B. AREA A AREA B Unscrew the Venturi Jet using a 2.5mm Allen Key Refit the correct Venturi Jet into the insert disc and hand tighten firmly...
  • Page 5 UPGRADING FROM UNEQUAL TO MAINS PRESSURE Remove the insert disc using long nosed pliers by carefully Remove the handle and disassemble the mixer: inserting the nose of the pliers into the indicated areas A & B. AREA A AREA B Refit the seal and then insert disc using the long nose pliers, Unscrew the Venturi Jet using a 2.5mm Allen Key ensuring that the locating pins go into the corresponding sockets.
  • Page 6 Thank you for purchasing a Felton Product for your home. Felton stand behind our products and wish to provide you with the warranty set out overleaf. In order to obtain a Lifetime Extension Warranty to the standard warranty, please read and follow the terms and conditions of your warranty (on reverse).