5 Mounting
Figure 7: Recommended clearances(Dimensions in mm)
5.2

Mounting the Inverter

Additionally required mounting material (not included in the scope of delivery):
☐ 3 screws, suitable for the support surface and the weight of the inverter (diameter: minimum
6 mm)
☐ 3 washers, suitable for the screws (outer diameter: minimum 18 mm)
☐ Where necessary, three screw anchors suitable for the support surface and the screws
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while being transported or
mounted.
• Transport and lift the product carefully. Take the weight of the product into account.
• Wear suitable personal protective equipment for all work on the product.
Procedure:
1.
Risk of injury due to damaged cables
There may be power cables or other supply lines (e.g., gas or water) routed in the wall.
• Ensure that no lines are laid in the wall which could be damaged when drilling holes.
26
STP3-6-3AV-40-BE-en-13
CAUTION