Hazard information
qualified electricians (to VDE 0100) are permitted
to carry out work on the 230 V mains. Applicable
accident prevention regulations must be com-
plied with whilst such work is being carried out.
To avoid electric shocks from the device, please
disconnect the mains voltage (trip the miniature
circuit-breaker). Non-compliance with the instal-
lation instructions can cause fire or introduce
other hazards.
No SELV/PELV circuits may be connected to the
terminals of the inputs and outputs.
When connecting to the device terminals, take
the permissible cables and cable cross sections
into account.
Connected loads require sufficient insulation.
Exceeding this capacity could lead to the de-
struction of the device, fires or electric shocks.
Please take the technical data (in particular the
maximum permissible switching capacity of the
load circuits and the type of load to be connected)
into account before connecting a load. Do
notexceed the capacity specified for the device.