National Instruments VXI-AT2023 Getting Started page 48

Software for isc 386/ix
Table of Contents

Advertisement

Appendix A
MXIbus
Capability Code
MA32, MA24, MA16
SA32, SA24, SA16
MD32, MD16, MD08(EO)
SD32, SD16, SD08(EO)
MBLOCK
SBLOCK
SC
FAIR
TERM
IH
IR
Electrical
Source
+5 VDC
-5.2 VDC
-2 VDC
Environmental
Component temperature
Airflow
Relative humidity
© National Instruments Corporation
Master Mode A32, A24, and A16 addressing
Slave Mode A32, A24, and A16 addressing
Master Mode D32, D16, and D08 data sizes
Slave Mode D32, D16, and D08 data sizes
Master Mode block transfers
Slave Mode block transfers
Optional MXIbus System Controller
Optional MXIbus fair requester
Can accept MXIbus termination resistors
Interrupt Handler
Interrupt Requester
DC Current Ratings
Typical
Maximum
5.25 A
6.7 A
300 mA
400 mA
100 mA
125 mA
0° to 70° C operating;
-40° to 85° C storage
3.5 liters/sec for 10° rise
10% to 90% noncondensing operating;
0% to 95% noncondensing storage
A-5
Description
Dynamic Current
0.67 A
50 mA
20 mA
VXI-AT2023/NI-VXI ISC 386/ix Getting Started
Specifications

Advertisement

Table of Contents
loading