7. Troubleshooting

If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
The ICM does not
work.
The cooler does not
cool enough. The
products are warm.
13
ALL ACCESS TO THE COOLING SYSTEM AND ELECTRICAL PARTS
(CHANGING A LAMP OR REFRIGERATION DECK) MUST BE PERFORMED
BY AUTHORIZED SERVICE PERSONNEL ONLY.
All models are equipped with HC refrigerant. All service
operations on cooling mechanism & gas charging should be
performed in a well ventilated environment or in open air. Do not
smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door of the cooler closed during cooling mechanism
maintenance. The appliance could be unstable when the compressor
is disassembled. If the compressor needs to be replaced, use
adequate support to fix the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
POSSIBLE REASONS
Power cord not plugged in.
No power coming through the
socket.
The thermostat setting is not correct. Rotate the thermostat knob clockwise.
The ICM has recently been reloaded
with warm products. It takes 8-16
hours to cool them down.
The ICM is loaded in such a way
that the air circulation in the interior
is getting blocked.
The door does not seal properly.
HANDLING
Plug it in.
Check for fuse/MCB on the mains.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be