Vent-Axia MFQ35014 Installation And Wiring Instructions

Vent-Axia MFQ35014 Installation And Wiring Instructions

Square mixed flow fans

Advertisement

Quick Links

Square Mixed Flow Fans (MFQ)
Installation and Wiring Instructions
Vent-Axia controls must be used with this fan!
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING
INSTALLATION.
THESE INSTRUCTIONS SHOULD BE LEFT WITH THE END USER.
MFQ35014
MFQ40014
MFQ45014
MFQ50014
MFQ40034
MFQ45034
MFQ50034
MFQ56034
MFQ56036
MFQ63034
MFQ63036

Advertisement

loading
Need help?

Need help?

Do you have a question about the MFQ35014 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vent-Axia MFQ35014

  • Page 1 Installation and Wiring Instructions MFQ35014 MFQ40014 MFQ45014 MFQ50014 MFQ40034 MFQ45034 MFQ50034 MFQ56034 MFQ56036 MFQ63034 MFQ63036 Vent-Axia controls must be used with this fan! PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION. THESE INSTRUCTIONS SHOULD BE LEFT WITH THE END USER.
  • Page 3 Air moving equipment may generate unacceptable noise levels when in operation. It may be necessary to take appropriate action to reduce sound levels. A range of products are available for this purpose from Vent-Axia. This appliance is not intended for use by persons (including children) with reduced...
  • Page 4: Fan Mounting

    Plan the installation carefully, taking into consideration the safety points noted above, before securely fixing the fan using appropriate screws, bolts, rubber bushes, etc. A range of accessories are available from Vent-Axia to assist installation including flexible connectors, mounting feet, anti-vibration mounts and attenuators.
  • Page 5: General Wiring Instructions

    TK switch connected into the circuit. To comply with safety standards, this product must be installed with Vent-Axia overload relays or controls. 5. Connect the power supply from the local isolator (via any appropriate controls if fitted) to the terminal box via the supplied cable gland using between 4.0mm and...
  • Page 6: Routine Inspection/Maintenance

    INSTALLER AND ELECTRICAL CONTRACTOR RESPONSIBILITY Vent-Axia Ltd, as suppliers of the equipment cannot be responsible for the final installation and electrical connection of the product on site. We have made reasonable effort to offer guidance and assistance but the installer and electrical contractor on site have a responsibility for ensuring the equipment is safely and securely installed and electrically/mechanically safe in accordance with statutory requirements.
  • Page 7 Vent-Axia D.O.L. Starter/Overload and Speed Controller stock reference numbers: Product Starter Overload Electronic Auto Controller Transformer Controller MFQ35014 444744 444701 10303103A 10314103A MFQ40014 444744 444702 10303103A 10314103A MFQ45014 444744 444703 10303106A 10314105A MFQ50014 444744 444705 10303110A 10314109A MFQ40034 444747 444700...
  • Page 8 Fig. 2 Single phase MFQ Connected to a D.O.L. Starter and an Auto Transformer Speed Controller with no TK connections Fig. 3 Single phase MFQ Connected to an Electronic Speed Controller...
  • Page 9 Fig. 4 Three phase MFQ Connected to a D.O.L. Starter Fig. 5 Three phase MFQ Connected to an Auto Transformer Speed Controller...
  • Page 10 Notes:-...
  • Page 11 Notes:-...
  • Page 12 SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560593 Fax: 01293 539209 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 409582B 0716...