Disarming Diagnostics; System Status Chirps - Automate AM7 Owner's Manual

Dei automate am7: owners guide
Hide thumbs Also See for Automate AM7:
Table of Contents

Advertisement

the system was armed, until that input ceases. Three seconds
after that input ceases, the security system will resume normal
monitoring. For example, if your vehicle has an interior light exit
delay and you arm your security system before the interior light
turns off, you may hear a second Bypass Notification chirp.
Once the light turns off, however, the security system resumes
normal monitoring.
note: Bypass Notification does not occur when the sys-
tem is in Silent Mode or if the notification chirps have
been programmed off by the installer.

disarming diagnostics

Extra chirps that are heard when disarming the system are the
Tamper Alert. If four chirps are heard when disarming the
system, then the security system was triggered in your absence. If
five chirps are heard when disarming the system, a zone was trig-
gered so many times that the Nuisance Protection
bypassed that zone. In either case, the status LED will indicate
which zone was involved (see Table of Zones section). The secu-
rity system will retain this information in its memory and chirp
four or five times each time it is disarmed, until the next time
that the ignition is turned on.

system status chirps

The siren will chirp when arming/disarming the system. The
pattern of chirps will audibly report the system's status as
described below.