Electrical Connections
Switch OFF the electricity supply at the consumer unit.
The power cable entry point is shown on the diagram.
Electrical connection to be made at the terminal block as
follows:
Earth cable to the terminal marked with the Earth symbol
Neutral cable to the terminal marked N
Live cable to the terminal marked L
Important: Terminals must be fully tightened onto the
cables ensuring that no cable insulation is trapped under
the screws.
It must be metal to metal. Loose connections can result in
the cables overheating, ensure all terminal screws are fully
tightened.
The supply cable earth conductor must be sleeved. The
supply cable must be secured by routing through conduit or
in trunking or by being embedded in the wall in accordance
with current I.E.E Regulations.
Warning: Do not switch on power to the shower
unit until the cover has been fully fitted.
•
Plug in the cable from the cover (10) to the connection
(10a) inside the unit.
•
Rotate the temperature control knob (6) fully anti-
clockwise
(full cold).
•
Rotate the splined temperature control spindle (6a) fully
anti-clockwise.
•
Locate cover in position ensuring wiring is not trapped.
Note: slight adjustment of the knob may be required to
locate cover correctly.
•
Secure using the 4 cover fixing screws supplied and fit
screw covers.