BFT SHYRA AC SL Installation Manual page 23

Hide thumbs Also See for SHYRA AC SL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Terminal
70
71
72
73
74
75
Y
#
(*) If "D" type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "A" - PARAMETERS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Work time [s]
TABLE "B" - LOGICS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
DIP
Logic
Default
Transmitter
1
ON
programming
2
BAR / 8K2
OFF
Photocell input
3
OFF
check
4
Edge input check
OFF
INSTALLATION MANUAL
Definition
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
PHOT (*)
Operation according to "PHOTOCELL/PHOTOCELL DURINg CLOSINg" logic. If not used, leave
jumper inserted.
FAULT 1
Test input for safety devices connected to PHOT.
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
OFF
BAR /
OFF
BAR CL /
BAR TEST /
BAR CL TEST /
BAR 8K2 /
OFF
BAR CL 8K2
(*)
OFF
ON
ON
FAULT 2
Test input for safety devices connected to BAR / BAR CL
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter's
SHIELD
range is limited, move the antenna to a more suitable position.
+
+
+
min.
max.
default
Waiting time before automatic closing.
0
120
0
NOTE: Set to 0 if not used.
SHYRA AC SL
Sets the motor working time (from 0 to 90s), after which the motors stop.
In the case where electrical limit switches are used, add a few extra seconds after the gate leaf
stopping time.
5
120
50%
SHYRA AC BA
Motor(s) work time set to 10 seconds.
trimmer at minimum: input 60-61 CLOSE.
trimmer at maximum: input 60-61 START.
Cross out
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
ON
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input configured as Bar 8k2 (Fig.g). Input for resistive edge 8K2.
ON
The command reverses movement for 1 sec.
Input configured as Bar, safety edge (Fig.g).
OFF
The command reverses movement for 1 sec..
ON
Enable safety check on the PHOT input. (Fig.g)
OFF
Safety check on PHOT input not enabled. (Fig.g)
ON
Enable safety check on the BAR input. (Fig.g)
OFF
Safety check on BAR input not enabled. (Fig.g)
Description
Safety edge
Safety edge
check
operation
dip
dip
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
Description
NC input, no verification, reversal while
opening and closing (BAR)
NC input, no verification, reversal only
when closing, stop when opening (BAR
CL)
NC input, with verification, reversal
while opening and closing (BAR TEST)
NC input, with verification, reversal only
when closing, stop when opening (BAR
CL TEST)
8K2 input, reversal when opening and
closing (BAR 8K2)
8K2 input, reversal only when closing,
stop when opening (BAR CL 8K2)
SHYRA -
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shyra ac sl 120Shyra ac baShyra ac ba 120

Table of Contents