OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying,
the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it
correctly to resume operation.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will
go in to defrost mode. Following completion of the defrost mode, the unit will return to the
previously operating settings.
When the unit is running in a room with a temperature between 5
defrost mode roughly every 30 minutes.
When the unit is running in a room with a temperature between 12
the defrost mode roughly every 45 minutes.
HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION
When the humidity of the room is 2% lower than the desired humidity the compressor will
turn off automatically but the fan will continue to operate to ensure that the air within the
room is not stale. The unit will use only a minimal amount of energy in fan mode.
When the humidity of the room is equal to or higher than the desired humidity the
compressor will restart after a 3 minutes delay to protect the compressor.
AUTO-RESTART (on some models)
If the unit stops unexpectedly due to the power cut, it will restart with the previous function
selected automatically when the power resumes, and the 3 minute compressor protection
has elapsed.
POWER
After the unit has stopped, to protect the compressor it is not recommended to resume
operation for at least 10 minutes. Operation can resume after this period lapses. When the
unit is restarted there is a 3 minutes delay before compressor will start.
LIGHTWEIGHT PORTABLE DESIGN ON CASTORS
The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit
make it easy to move from room to room.
Your dehumidifier contains an advanced micro-CPU controlled device which is capable of
self-diagnostics. The LCD display may also show the error and protections codes.
10
o
o
C and 12
C, it will enter
o
o
C and 20
C, it will enter