Konica Minolta bizhub 4750 Service Manual page 9

Security function
Hide thumbs Also See for bizhub 4750:
Table of Contents

Advertisement

Security Function Ver. 1.01 Sep. 2014
• Each time a wrong CE password is entered, the CE password illegal access count
is incremented by one.
When the access to the Service Mode has been successful with the correct CE
password entered, the CE password illegal access count is cleared and reset to 0.
• When "ON" is set for Enhanced Security Mode, access to the Service Mode
through the CE Password is restricted by up to 3 times.
If the CE password illegal access count exceeds 3 times, the machine is then set
into an access lock state.
It is necessary for unlocking the access lock state to restart the machine with main
power switch OFF and ON.
(The illegal access count value is cleared by machine's restart)
• To go from the CE password screen to another, enter the CE password and call the
Service Mode menu to the screen. Then, quit the Service Mode.
6. Touch [OK] twice.
7. The Service Mode screen will appear.
NOTE
• If you leave the site with the Service Mode setting screen being displayed, unau-
thorized changes could occur for any set values. When you finish the setting of
Service Mode, or if you have to leave the site by necessity when the Service Mode
has been set, be sure to press [Close] and log-out from the Service Mode.
6. Accessing the Service Mode
A6F7S1E002DA
5