Summary Of Maintenance And Inspection Intervals - Bauer S300 Original Operating Manual

Table of Contents

Advertisement

For example, Fig. 13-16, right and middle images, shows plating that has been worn down on the outer
edges of the auger, but recoating is still possible because the plating on the face side is still retained up to
20%, meaning that the actual auger blade has not yet been damaged. Excluding the plating, the auger
blades have a thickness in this area of 10 mm, meaning that the remaining plating can be determined
very precisely with a depth caliper.
The left image in Fig. 13-16 shows a auger on which the axial plating has been worn down completely on
the outer edges of the auger blade. In addition, the auger thickness itself has been reduced almost to
half. A cost-effective recoating is not possible in this case since the base stiffness of the auger blade
would no longer suffice for sufficient bonding of the plating. A new auger is therefore required.
Fig. 13-16 Indications of the need for recoating the auger

13.6 SUMMARY OF MAINTENANCE AND INSPECTION INTERVALS

WARNING
Daily:
Visual inspection of the solid cake and the effluent
Visual inspection of the machine and gearbox seals (see section
13.1.1 Fig. 13-3 flange inflow housing inspection opening)
Every 125 operating hours (or weekly):
Supply with sealing medium (see section 13.1.1)
Every 1-3 months
Inspection and cleaning of the housing, screen, guide rails,
plastic profile rails, auger, housing protection ring (see section
13.2 - 13.5)
Readjust scraping bolts (see section 13.4 Fig. 13-14)
Every 6 months:
Check gearbox oil level
After 10.000 operating hours (no later than every 2 years)
Geared motor oil change (see the gearbox and motor documen-
tation for oil quantity and type)
Inspect the bearing (see the gearbox and motor documentation
for details)
28
S
Check the operational safety of the machine before every start !
Operating Manual for BAUER Separator S300

Advertisement

Table of Contents
loading