5 ELECTRICAL CONNECTION

The electric motor is equipped with a terminal strip. Like all electrical connections, the external motor con-
trol must be connected properly by a qualified electrician.
DANGER
Work on electrical and electronic components of the system may only be performed
by a trained electrician or otherwise appropriately trained personnel under the guid-
ance and supervision of a trained electrician in accordance with the applicable elec-
trical and electronic regulations.
WARNING
Fuses do not protect the motor from overloads; they only protect the electrical sup-
ply lines or switching systems from damage in event of a short-circuit.
The electric motor must always be protected with a motor protection circuit breaker that must be set to the
rated current shown on the type plate depending on the motor wiring. Only motor protection circuit break-
ers certified according to the following standards may be used: IEC, UL, CSA.
WARNING
Set the motor protection circuit breaker to the correct value, never above the max.
rated current according to the type plate.
It is recommended that the corresponding electrical control for the separator or for the separator and the
submersed motor pump be purchased from BAUER since it will be already adapted to the corresponding
drive motors.
WARNING
Ensure the correct rotation direction of the auger shaft when making the electrical
connection!
Fig. 5-1 Rotation direction of the auger
Operating Manual for BAUER Separator S300
In forward motion, the auger shaft turns counterclockwise
(as viewed from the output regulator toward the geared mo-
tor).
Viewing
direction
If this is not the case, two of the current-carrying conductors
at the geared motor connection or in the switch cabinet must
be swapped.
13