Connect To Ground - TP-Link TL-SF1016DS Installation Manual

10/100mbps unmanaged switch
Hide thumbs Also See for TL-SF1016DS:
Table of Contents

Advertisement

10/100Mbps Unmanaged Switch
Cable
2 to 5kVA
powerline
>5kVA
powerline
Device
Switch case
Transformer room
Elevator tower
Air-conditioner room
3.2

Connect to Ground

Connecting the device to ground is to quickly release the lightning over-voltage and
over-current of the device, which is also a necessary measure to protect the body from
electric shock.
In different environments, the device may be grounded differently. The following
will instruct you to connect the device to the ground in two ways, connecting to the
grounding bar or connecting to the ground via the power cord. Please connect the
device to ground in the optimum way according to your specific operation environment.
Connecting to the Grounding Bar
If the device is installed in the Equipment Room, where a grounding bar is available, you
are recommended to connect the device to the grounding bar as shown in the following
figure.
Figure 3-1
12
Lightning Protection
Pave Way
Parallel cabling
One is in the grounded metal raceway or metal pipe
The both are in the grounded metal raceway or
metal pipe
Parallel cabling
One is in the grounded metal raceway or metal pipe
The both are in the grounded metal raceway or
metal pipe
Min Distance (m)
1.00
2.00
2.00
2.00
Connecting to the Grounding Bar
Switch (Rear Panel)
Grounding Terminal
Ground Cable
Grounding Bar
Min Parallel
Length (mm)
300
150
80
600
300
150