Technical specifications
DC output
Configurable
(Input or Output)
1
0 V DC (-)
2
DC output 12 V, max 50 mA
A
I/O configured as input
B
I/O configured as output
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant
limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output
current limited to ≤5 A.
RS485/RS422 connector
Two terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such as pan-tilt devices.
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–4
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive load, e.g.
a relay, a diode must be connected in parallel with the load, for
protection against voltage transients.
74
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA