Hide thumbs Also See for P1364-E:

Advertisement

Quick Links

AXIS P13-E Series
AXIS P1364-E Network Camera
AXIS P1365-E Mk II Network Camera
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P1364-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Axis P1364-E

  • Page 1 AXIS P13-E Series AXIS P1364-E Network Camera AXIS P1365-E Mk II Network Camera Installation Guide...
  • Page 2 Low Voltage (LVD) Directive 2006/95/EC. See Safety Every care has been taken in the preparation of this on page 3 . document. Please inform your local Axis office of any • Restrictions of Hazardous Substances (RoHS) Directive inaccuracies or omissions. Axis Communications AB cannot 2011/65/EU.
  • Page 3 FAQ database. ことがあります。この場合には使⽤者が適切な対 Search by product, category, or phrase 策を講ずるよう要求され ることがあります。 本 • report problems to Axis support staff by logging in to 製品は、シールドネットワークケーブル(STP)を your private support area 使⽤して接続してください。また適切に接地し • chat with Axis support staff てください。...
  • Page 5: Hazard Levels

    AXIS P13-E Series Safety Information Read through this Installation Guide carefully before installing the product. Keep the Installation Guide for future reference. Hazard Levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 6: Safety Instructions

    Battery The Axis product uses a 3.0 V CR2032 lithium battery as the power supply for its internal real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years. Low battery power affects the operation of the RTC, causing it to reset at every power-up. When the battery needs replacing, a log message will appear in the product’s server report.
  • Page 7 WARNING • Risk of explosion if the battery is incorrectly replaced. • Replace only with an identical battery or a battery which is recommended by Axis. • Dispose of used batteries according to local regulations or the battery manufacturer's instructions.
  • Page 9: Installation Steps

    AXIS P13-E Series Installation Guide This Installation Guide provides instructions for installing AXIS P1364-E Network Camera or AXIS P1365-E Mk II Network Camera on your network. For other aspects of using the product, see the User Manual available at www.axis.com Installation Steps 1.
  • Page 10: Hardware Overview

    AXIS P13-E Series Hardware Overview Status LED Built-in microphone microSD card slot Audio in Audio out Network connector (PoE) Power LED Network LED Control button 10 I/O connector 11 Iris connector 12 Not used 13 RS485/422 connector...
  • Page 11 AXIS P13-E Series AXIS P1364-E AXIS P1365-E Mk II Focus ring Lock screw for focus ring Zoom puller Safety wire Heater connector Network connector (PoE OUT) Status LED indicator Network connector (PoE IN) Heater cable Cable gasket M20 (2x)
  • Page 12: Wall Mount

    AXIS P13-E Series Drill-out (2x) Intrusion alarm switch 10 Holder screw T20 (2x) 11 Camera screw T20 12 Pin 13 Holder 14 Window 15 Top cover 16 Weather shield Wall Mount Network cable (route through wall bracket) Power cable (route through wall bracket) (for products equipped with power...
  • Page 13 AXIS P13-E Series LED Indicators Note • The Status LED can be configured to be unlit during normal operation. To configure, go to Setup > System Options > Ports & Devices > LED. See the online help for more information.
  • Page 14: Connectors And Buttons

    When a signal is received the state changes and the input becomes active (shown under System Options > Ports & Devices). Audio Connector The Axis product has the following audio connectors: • Audio in (pink) – 3.5 mm input for a mono microphone, or a line-in mono signal.
  • Page 15: Specifications

    SD card. Use your fingers to insert and remove the card. • Risk of data loss and corrupted recordings. Do not remove the SD card while the product is running. Disconnect power or unmount the SD card from the Axis product’s webpages before removal.
  • Page 16: Power Consumption

    Humidity AXIS P1364-E -40 °C to 50 °C 10–100% RH (condensing) (-40 °F to 122 °F) AXIS P1365-E Mk II -40 °C to 50 °C 10–100% RH (condensing) (-40 °F to 122 °F) Important When the ambient temperature is below 0 ºC (32 ºF), start-up could take up to 60 minutes.
  • Page 17 AXIS P13-E Series 3– Configurable Digital input – Connect to pin 1 to activate, 0 to max 30 V DC (Input or or leave floating (unconnected) to deactivate. Output) Digital output – Connected to pin 1 when 0 to max 30 V DC, open...
  • Page 18: Cable Area

    To create extra cable holes, open the drill-outs located in the bottom of the housing. See Hardware Overview on page 10. For information about accessories, such as cable gaskets and cable glands that allow for other cable areas, see www.axis.com...
  • Page 19: Connection Diagrams

    For information about regulatory requirements, see Regulatory Information on page 2 • Be careful not to scratch, damage or leave fingerprints on the window because this could decrease image quality. The Axis product can be installed with the cables routed through or along the wall.
  • Page 20: Install The Wall Mount

    4. Fasten the wall bracket to the wall by tightening the screws. Note • For detailed instructions, see the wall mount’s Installation Guide supplied in the package and available on www.axis.com Attach the Housing to the Wall Mount NO TICE...
  • Page 21 AXIS P13-E Series Bottom cover Bottom cover screw T20 (4x) Cable gasket M20 (2x) 3. Push the network cable through the cable gasket. NO TICE TICE TICE If the network cable has a premounted network connector, remove the cable gasket and use the connector guard to prevent tearing of the cable gasket.
  • Page 22 AXIS P13-E Series 5. Make sure that the cable gasket is fitted properly. 6. If connecting an auxiliary device, for example an I/O, audio, or external power device, to the camera, repeat the steps above as applicable to the specific device.
  • Page 23: Connect The Camera

    AXIS P13-E Series Screw T20 (4x) Wall bracket Bracket adjustment screw T30 Connect the Camera 1. If applicable, connect external I/O devices or audio devices to the camera. It may be necessary to disconnect the intrusion alarm switch first. 2. Connect the heater cable to the heater connector in the bottom cover.
  • Page 24: Access The Product

    9. If required, loosen the screws on the weather shield, adjust its position and tighten the screws. Access the Product AXIS IP Utility and AXIS Camera Management are recommended methods for finding Axis products on the network and assigning them IP addresses in Windows®. Both applications are free and can be downloaded from www.axis.com/techsup The product can be used with most operating systems and browsers.
  • Page 25: Adjust Focus With The Focus Assistant

    • If movements in front of the camera cannot be avoided, the Focus Assistant should not be used. • If the control button is not released within two seconds, AXIS Internet Dynamic DNS Service is enabled instead of the Focus Assistant.
  • Page 26: Reset To Factory Default Settings

    For the latest version of this document, see www.axis.com The User Manual is available at www.axis.com Visit www.axis.com/techsup to check if there is updated firmware available for your network product. To see the currently installed firmware version, go to Setup > About.
  • Page 27: Warranty Information

    AXIS P13-E Series Visit Axis learning center www.axis.com/academy for useful trainings, webinars, tutorials and guides. Warranty Information For information about Axis’ product warranty and thereto related information, see www.axis.com/warranty/...
  • Page 28 Installation Guide Ver. M5.6 AXIS P13-E Series Date: February 2016 © Axis Communications AB, 2015 Part No. 1540128...

This manual is also suitable for: