Maintenance activities

In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals, preferably yearly. This maintenance should be
carried out by your local Daikin technician (see installation manual).
The only maintenance which may be required by the operator is:
I
keeping the remote controller clean by means of a soft damp
cloth,
I
checking if the water pressure indicated on the manometer is
above 1 bar.
If the supply cord is damaged, it must be replaced by the
manufacturer, its agent or similar qualified persons in order
to avoid hazards.
During longer periods of standstill, e.g. during summer with
a heating only application, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic
repetitive movement of the pump in order to prevent it from
getting jammed.

Important information regarding the refrigerant used

This product contains fluorinated greenhouse gases. Do not vent
gases into the atmosphere.
Refrigerant type:
R134a
(1)
GWP
value:
1430
(1)
GWP = global warming potential
Fill in the label as follows:
Contains fluorinated greenhouse gases
RXXX
=
1
6
GWP: XXX
2
=
2
1
1
+
2
=
GWP ◊ kg
=
1000
1
From the multilingual fluorinated greenhouse gases label peel off
the applicable language and stick it on top of 1.
2
Factory refrigerant charge: see unit name plate
3
Additional refrigerant amount charged
4
Total refrigerant charge
5
Greenhouse gas emissions of the total refrigerant charge
expressed as tonnes CO
6
GWP= Global warming potential
CAUTION
In Europe, the Greenhouse gas emissions of the total
refrigerant charge in the system (expressed as tonnes
CO
-equivalent) is used to determine the maintenance
2
intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant x Total refrigerant charge [in
kg] / 1000
Operation manual
19
1
kg
2
kg
3
kg
4
5
tCO
eq
2
-equivalent
2
T
ROUBLESHOOTING
The guidelines below might help to solve your problem. If you cannot
solve the problem, consult your installer.
P
OSSIBLE CAUSES
No readings on the remote controller
(blank display)
One of the error codes appears
The schedule timer does work but
the programmed actions are
executed at the wrong time
(e.g. 1 hour too late or too early)
The domestic hot water schedule
timer is programmed but does not
work.
Capacity shortage
D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Your product is marked with this symbol. This means that
electrical and electronic products shall not be mixed with
unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.
Indoor unit for air to water heat pump system and options
C
ORRECTIVE ACTIONS
• Check if the mains power is still
connected to your installation.
• The benefit kWh rate power supply is
active (see installation manual).
Consult your local dealer.
Refer to the installation manual for a
detailed list of error codes.
Check if the clock and the day of the
week are set correctly, correct if
necessary.
In case the
icon is not displayed,
push the
button to enable the
schedule timer.
Consult your local dealer.