Field Settings Table - Daikin EKHBRD011ADV17 Operation Manuals

Indoor unit for air to water heat pump system and options
Hide thumbs Also See for EKHBRD011ADV17:
Table of Contents

Advertisement

Field settings table

First
Second
code
code
Setting name
0
Remote control setup
00
Installation related setting
01
Installation related setting
02
Not applicable. Do not change the default value.
03
Status: space heating schedule timer mode
1
Automatic storage timing for domestic water heating
00
Status: night time storage
01
Night time storage start time
02
Status: day time storage
03
Day time storage start time
2
Automatic setback function
00
Status: setback operation
01
Setback operation start time
02
Setback operation stop time
3
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_Ti)
03
Set point at high ambient temperature (Hi_Ti)
4
Disinfection function
00
Status: disinfection operation
01
Disinfection operation day selection
02
Disinfection operation start time
5
Automatic setback and disinfection set point
00
Set point: disinfection operation temperature
01
Disinfection operation time duration
02
Leaving water setback temperature
03
Room setback temperature
6
Option setup
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
7
Option setup
00
Installation related setting
01
Not applicable. Do not change the default value.
02
Installation related setting
03
Installation related setting
04
Installation related setting
8
Option setup
00
Installation related setting
01
Installation related setting
02
Emergency mode
03
Status: low noise level
04
Installation related setting
Operation manual
17
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
2
2~3
0
–5~5
1 (ON)
1 (ON)
0/1
1 (ON)
0/1
1:00
0:00~23:00
0 (OFF)
0/1
15:00
0:00~23:00
1 (ON)
0/1
23:00
0:00~23:00
5:00
0:00~23:00
–10
–20~5
15
10~20
70
25~80
45
25~80
1 (ON)
0/1
Fri
Mon~Sun
23:00
0:00~23:00
70
60~75
10
5~60
5
0~10
18
17~23
0 (OFF)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
0
0/2
1 (ON)
0/1
0 (OFF)
0 (A)
0/1
0 (OFF)
0/1
0 (OFF)
0/1
1 (ON)
0/1
1 (ON)
0/1
0 (OFF)
0/1
1
1~3
0
0~2
EKHBRD011~016ADV17+Y17
Indoor unit for air to water heat pump system and options
Step
Unit
1
0.5
°C
1:00
hour
1:00
hour
1:00
hour
1:00
hour
1
°C
1
°C
1
°C
1
°C
1:00
hour
5
°C
5
min
1
°C
1
°C
1
1
1
4P402192-1B – 2017.09