Daikin EKHBRD014AAV1 Operation Manual

Daikin EKHBRD014AAV1 Operation Manual

Indoor unit for air to water heat pump system and options
Hide thumbs Also See for EKHBRD014AAV1:

Advertisement

Quick Links

OPERATION MANUAL
Indoor unit for air to water heat pump system
and options
EKHBRD011AAV1
EKHBRD014AAV1
EKHBRD016AAV1
EKHBRD011AAY1
EKHBRD014AAY1
EKHBRD016AAY1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKHBRD014AAV1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin EKHBRD014AAV1

  • Page 1 OPERATION MANUAL Indoor unit for air to water heat pump system and options EKHBRD011AAV1 EKHBRD014AAV1 EKHBRD016AAV1 EKHBRD011AAY1 EKHBRD014AAY1 EKHBRD016AAY1...
  • Page 2: Table Of Contents

    EKHBRD011AAV1 EKHBRD011AAY1 Indoor unit for air to water heat pump system Operation manual EKHBRD014AAV1 EKHBRD014AAY1 and options EKHBRD016AAV1 EKHBRD016AAY1 ONTENTS Page CAREFULLY READ THIS OPERATION MANUAL Introduction ..................1 BEFORE USING THE UNIT. IT WILL TELL YOU HOW TO USE THE UNIT PROPERLY AND HELP YOU IF ANY General information ..............
  • Page 3: Quick Start-Up Of The Unit

    Manual storage UICK START UP OF THE UNIT Push and hold the w button for In this chapter the step-by-step procedure is explained for starting up 5 seconds both space heating and domestic water heating. The more detailed information of how the unit must be operated is explained in the chapter "Operation of the unit"...
  • Page 4: Remote Controller Buttons And Icons

    11. TEMPERATURE DISPLAY Remote controller buttons and icons The display shows the current temperature of the installation either leaving water temperature or actual room temperature. 6 23 When changing the room temperature set point, the set point will be flashing for 5 seconds and then return to the actual room temperature.
  • Page 5: Setting The Clock

    24. DOMESTIC WATER HEATING BUTTON Setting the clock This button enables or disables the different domestic hot water modes in combination with the schedule timer button. After initial installation, the user can set the clock and day of the week. This button is not used when the domestic hot water tank is not The remote controller is equipped with a schedule timer that enables installed.
  • Page 6: Leaving Water Temperature Control

    Leaving water temperature control Selecting space heating operation Use the y button to switch ON/OFF space heating (h). In this mode, heating will be activated as required by the water temperature set point. The set point can be set manually, through the Icon h appears on the display as well as the corresponding schedule timer or weather dependent (automatic).
  • Page 7: Domestic Water Heating Operation ( W )

    Field settings define the parameters for the weather dependent The setback function is configured through field settings. Refer to the operation of the unit. Refer to the chapter "Field settings" on page 15 chapter "Field settings" on page 15 for a detailed description how to for a detailed description how to set one or more field settings.
  • Page 8: Automatic Storage

    Automatic storage NOTE If weather dependent domestic water heating is In this mode, the indoor unit will deliver hot water to the domestic hot enabled [b-02], the storage temperature will be set water tank based on the daily fixed pattern. This mode will continue automatically and the field setting [b-03] will be of no until the storage temperature set point is reached.
  • Page 9: Reheat

    Disinfection operation The storage temperature set point is a field setting. Refer to the chapter "Field settings" on page 15 for a detailed description how to This mode will disinfect the domestic hot water tank by periodically set one or more field settings. heating the domestic water to a specific temperature.
  • Page 10: Other Operation Modes

    Other operation modes Simultaneous demand of space heating and domestic water heating Start up operation (d) The unit can not perform domestic water heating and space heating During start up, the d icon displays, indicating that the heat at the same time. If both modes are requested at the same time, the pump is starting up and is not working in a steady state condition.
  • Page 11: Schedule Timer Operation

    Operation example: Schedule timer based on temperature set Schedule timer operation points. In schedule timer operation, the installation is controlled by the When setback function is enabled, the setback operation will have schedule timer. The actions programmed in the schedule timer will be priority over the scheduled action in the schedule timer.
  • Page 12: Domestic Water Heating

    Domestic water heating Operation example: Schedule timer based on ON/OFF instruction. When setback function is enabled, the setback operation will have Domestic water heating can be done through several standard priority over the scheduled action in the schedule timer if ON operation modes: instruction is active.
  • Page 13: Programming And Consulting The Schedule Timer

    Programming space heating Programming and consulting the schedule timer Programming the schedule timer is flexible (you can add, remove or alter programmed actions whenever required) and straightforward (programming steps are limited to a minimum). However, before programming the schedule timer, remind: Familiarize yourself with the icons and the buttons.
  • Page 14: Programming Quiet Mode Or Domestic Water Heating

    Programming quiet mode or domestic water heating Programming space heating is carried out as follows: NOTE Returning to previous steps in the programming procedure without saving modified settings is done by pressing the pr button. Press the < button to enter the programming/consulting mode. Select the operation mode you would like to program by means of the pi and pj buttons.
  • Page 15: Consulting Programmed Actions

    11 Press the < button for 5 seconds to store the programmed Deleting one or more programmed actions actions. Deleting one or more programmed actions is done at the same time If the < button is pressed when action number 3 is displayed, as storing the programmed actions.
  • Page 16: Field Settings

    Field settings When running through the field settings you may notice that there are some more field settings as there are The configuration of the Daikin system is done through field settings. mentioned in the "Field settings table" on page 16.
  • Page 17: Field Settings Table

    Field settings table Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Remote control setup User permission level — Room temperature compensation value –5~5 °C Not applicable. Do not change the default value. 1 (ON) —...
  • Page 18 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Automatic temperature compensation Leaving water temperature compensation value –5~5 °C Domestic hot water tank compensation value –5~5 °C Thermo ON/OFF admission –5~5 °C...
  • Page 19: Maintenance

    (blank display) at regular intervals, preferably yearly. This maintenance should be • The benefit kWh rate power supply is carried out by your local Daikin technician (see installation manual). active (see installation manual). One of the error codes appears Consult your local dealer.
  • Page 20 NOTES NOTES...
  • Page 22 4PW54466-1C...

Table of Contents