Follow This Step-By-Step
Guide To Using Your Generator
1
Remove generator from package
2
Add Oil
3
Connect Fuel
4
Start The Generator
Use the generator OUTDOORS in a WELL VENTILATED AREA.
DO NOT CONNECT electrical devices until AFTER the generator
is started.
Turn Fuel Switch ON (Fig. B)
Adjust the CHOKE to CLOSED position (Figure C)
Start the generator manually with the Recoil (Pull) Start. To use
the Electric Start, a battery must be purchased (sold separately).
Once the engine has started and runs for about a minute, move
the choke lever approximately half way towards the "Open/Run"
position. Wait an additional 30 seconds and then move the choke
lever completely over to the "Open/Run" position.
You can now connect electrical devices.
Fuel Switch
Gas Inlet
O
(Figure B)
(Figure A
)
Choke (Figure C)
Open
Closed
TOLL-FREE NATIONWIDE HELP LINE! 866-460-9436
Need Help? Do Not Return This Generator To The Store! Call Us First!
Visit our website for Troubleshooting & Frequently Asked Questions
Oil Type: SAE10W-30 Oil (Must add BEFORE first use)
Oil Capacity: 38 fluid oz (1.13 L)
Because this generator includes Low Oil Shut Off, the
generator will not start with low oil)
Connect regulator that was included with the
generator to Propane Fuel Tank and Gas Inlet.
(O-Ring should be attached to Gas Inlet.) (Fig A)
4
Recoil
Start
Monday-Friday 8:00-4:30 Central Time
www.sportsmanseriesbrand.com/generators
GEN7000LP
7,000 Surge / 6,000 Running Watts
LP LIQUID PROPANE FUEL
A BATTERY IS NOT INCLUDED! TO USE
THE ELECTRIC START FEATURE, BUY A
BATTERY WITH THESE SPECIFICATIONS:
Dimensions: 7 1/8" L x 6" H x 3" W
CCA (Cold Cranking Amps): 130 Min CCA
Comparable brands/models are:
12 Volt 22 Ah Sealed Lead Acid
Batterymart.com: SLA-12V22 or YB9A-A
Delco: CB9A-A
NAPA: 740-1872, 740-1858, 740-1837
Sears: 44043
GENERATOR SPECIFICATIONS:
• 120/240 Volt Operation
• 13 HP Engine, 4 Stroke OHV
• Air Cooled
• AVR Automatic Voltage Regulation
• Low Oil Shut Off
• Spark Arrestor
• UL Listed Electrical Components
• Engine Shut Off Switch
• Circuit Breaker & Power Outlets
• 1-12V DC Outlet
• 4-120V Outlets
• 1-120/240V Outlet
• Complies with EPA emissions
• Run time = 8 hours @ 50% load/ 20 lbs of
LP fuel
• Decibel Rating < 80 db
• Mobility Kit: Included
• Warranty: 1 YEAR limited
2
Add Oil
Battery Tray
Fuel Switch (Figure B)
4
Engine
Start

Advertisement

loading

Summary of Contents for Sportsman GEN7000LP

  • Page 1 Follow This Step-By-Step GEN7000LP Guide To Using Your Generator 7,000 Surge / 6,000 Running Watts LP LIQUID PROPANE FUEL Remove generator from package A BATTERY IS NOT INCLUDED! TO USE THE ELECTRIC START FEATURE, BUY A BATTERY WITH THESE SPECIFICATIONS:...
  • Page 2 GEN7000LP Outlets available on this generator, from left to right: 120V AC, 240/120 AC and 12V DC. 7,000 Surge / 6,000 Running Watts SEEK THE ADVISE OF A LICENSED ELECTRICIAN FOR 120V / 240V WIRING 120V AC 120V AC Reset 240/120V AC...