1

Remove generator from package

Oil Type: SAE10W-30 Oil (Must add BEFORE first use)
2

Add Oil

Oil Capacity: 38 fluid oz (1.1 L)
Because this generator includes Low Oil Shut Off, the generator
will not start with low oil)
3
If using Gasoline, add fuel to tank and turn Gasoline Fuel Petcock
Connect
to On (Fig C).
If using LP, connect regulator hose (Fig A) to Propane Fuel Tank
Fuel
and to the Gas Inlet (Fig B). Make sure the LPG adapter (Fig E) is
connected (Fig E).
If using NG, replace the LPG adapter with the NG adapter (Fig E).
(NOTE: Adapters are labeled with LPG and NG. (Fig F))
Directly connect to the NG system with a gas hose no less than
3/8" (inside diameter), no longer than 10 ft (3m), and to the gas
(Figure F)
inlet (Fig B). DO NOT use the LP regulator hose (Fig A) for NG.
Refer to the manual for detailed information.
4

Start The Generator

Use the generator OUTDOORS in a WELL VENTILATED AREA.
DO NOT CONNECT electrical devices until AFTER the generator
is started.
Turn Power Switch to ON
Adjust the CHOKE to CLOSED position (Figure D)
To start the generator manually, use the Recoil (Pull) Start. To
use the Electric Start, a battery must be purchased (sold
separately). Once the engine has started and runs for about a
minute, move the choke lever approximately half way towards
the "Open/Run" position. Wait an additional 30 seconds and then
move the choke lever completely over to the "Open/Run"
position. You can now connect electrical devices.
Regulator Hose (Figure A)
Fuel On
Fuel Off
Fuel Petcock (Figure C)
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
Choke (Figure D)
Choke
Open
Choke Closed
TOLL-FREE NATIONWIDE HELP LINE! 866-460-9436
This generator includes
ATTENTION
a built-in Carbon Monoxide
Warning Alert! The generator
will automatically shut-off if
dangerous levels of Carbon
ALERT!
Monoxide is detected.
Gas Inlet (Figure B)
Propane / NG
LP Gas Inlet
Gasoline Fuel Tank
(Figure A)
4
Recoil
Start
Monday-Friday 8:00 AM - 4:00 PM Central Time
GEN7500TRI
7,500 Surge / 6,000 Running Watts
TRI FUEL: GASOLINE, PROPANE OR NG
A BATTERY IS NOT INCLUDED! TO USE
THE ELECTRIC START FEATURE, BUY A
BATTERY WITH THESE SPECIFICATIONS:
Dimensions: 151 mm x 99 mm x 98 mm
(6" L x 3.8" H x 3.8" W)
CCA (Cold Cranking Amps): 130 Min CCA
Comparable brands/models are:
12 Volt 12 Ah Sealed Lead Acid
Model # CYLAZ10SXTA battery
GENERATOR SPECIFICATIONS:
• 120/240 Volt Operation
• 13.5 HP Engine, 4 Stroke OHV
• Air Cooled
• Displacement (CC): 420cc
• AVR Automatic Voltage Regulation
• Low Oil Shut Off
• Gasoline Fuel Max Capacity: 6.2 Gallon
• UL Listed Electrical Components
• Engine Shut Off Switch
• Circuit Breaker & Power Outlets
• 1-12V DC Outlet
• 4-120V Outlets
• 1-120/240V Outlet
• 1-120V RV Outlet
• Complies with EPA emissions
• Run time = 9 hours @ 50% load GAS
• Run time = 5 hours @ 50% load LPG
• Decibel Rating < 80 db
• Mobility Kit: Included
• If you are using a generator 3,000 ft. above
sea level, the generator may not function
properly because of air flow getting through
the carburetor.
• High Altitude Use: This generator is not
recommended for high altitude use 3,000 ft.
above sea level.
• Warranty: 2 YEAR Limited Emissions
Adapter (Figure E)
• Warranty: 1 YEAR Limited
*
SURGE WATTS / RUNNING WATTS
MAY BE REDUCED BY 20% WHEN USING
NATURAL GAS VS USING GASOLINE.
*
SURGE WATTS / RUNNING WATTS
MAY BE REDUCED BY 10% WHEN USING
PROPANE FUEL VS USING GASOLINE.
OIL IS NOT INCLUDED WITH THIS
GENERATOR. IT IS SOLD SEPARATELY.
Choose either LPG, Natural Gas or Gasoline fuel.
If using LPG gas, first connect the regulator
hose that was included with the generator to the
Propane Fuel Tank or the Natural Gas Tank.
Then connect the other end to the Gas Inlet.
(Make sure the O-Ring is attached to Gas Inlet.)
Make sure the LPG cylinder is vertical and
securely positioned. (LPG Tank not included).
If using Natural Gas, contact a qualified NG
2
technician before installation. The included
4
Battery Tray
regulator is ONLY for use with LPG tanks
Add
Engine
Oil
Start
Need Help? Call Customer Service!
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
SPORTSMAN
CO
NOTE
S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEN7500TRI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sportsman GEN7500TRI

  • Page 1 Follow This Step-By-Step GEN7500TRI Guide To Using Your Generator 7,500 Surge / 6,000 Running Watts TRI FUEL: GASOLINE, PROPANE OR NG Remove generator from package A BATTERY IS NOT INCLUDED! TO USE THE ELECTRIC START FEATURE, BUY A Oil Type: SAE10W-30 Oil (Must add BEFORE first use)
  • Page 2 GEN7500TRI Outlets available on this generator, from left to right: 12V DC, 120/240V AC, 120V AC RV, and 4 each 120V AC. 7,500 Surge / 6,000 Running Watts TRI FUEL- GASOLINE, PROPANE OR NG SEEK THE ADVISE OF A LICENSED...

Table of Contents