Magellan MG-6060 Programming Manual page 6

All-in-one wireless security system
Hide thumbs Also See for MG-6060:
Table of Contents

Advertisement

[094]
Zone Options
Option
[1]
Stay delay zones
[2]
Report zone restore
[3] & [4]
Tamper recognition options †
[3]
OFF
OFF
ON
ON
[5]
Generate tamper trouble if detected on bypassed zone
[6] & [7]
Wireless transmitter supervision options ‡
[6]
OFF
OFF
ON
ON
[8]
Generate supervision trouble if detected on bypassed zone
† For UL installations, Tamper recognition options must be enabled.
‡ For UL installations, Wireless supervision options must be enabled.
* For UL installations, if the zone is programmed as a wireless fire zone, supervision must be enabled and the check-in supervision time must be set at 80
minutes (section [096] option [7] on page 6).
[095]
Zone Options
Option
[1]
Zone 15 is hardwire zone 1 *
[2]
Zone 16 is hardwire zone 2 *
[3]
EOL (End-Of-Line) resistors †
[4]
Stay arm siren delay
[5]
Boat/car mode
[6] to [8]
Future use
* For UL installations, if either or both of the hardwired zones are enabled, then section [095] option [3] option must be enabled.
† This feature only applies to Magellan's onboard zone inputs. Section [095] options [1] and [2] must be ON in order to use this feature.
[096]
General Options
Option
[1] & [2]
Doorbell 1 tone options
[1]
OFF
OFF
ON
ON
[3] & [4]
Doorbell 2 tone options
[3]
OFF
OFF
ON
ON
[5]
Daylight savings time
[6]
AC power failure warning *
[7]
Check-in supervision time
[8]
RF Interferences detection *
* This option must be enabled for UL installations.
[097]
Reserved for future use
6
[4]
OFF
- Disabled
ON
- Trouble only
OFF
- Disarmed: Trouble only
- Armed: Follow zone's alarm type (page 3)
ON
- Disarmed: Audible alarm
- Armed: Follow zone's alarm type (page 3)
[7]
*
OFF
- Disabled
ON
- Trouble only
OFF
- Disarmed: Trouble only
- Armed: Follow zone's alarm type (page 3)
ON
- Disarmed: Audible alarm
- Armed: Follow zone's alarm type (page 3)
[2]
OFF
- Tone 1
ON
- Tone 2
OFF
- Tone 3
ON
- Tone 4
[4]
OFF
- Tone 1
ON
- Tone 2
OFF
- Tone 3
ON
- Tone 4
OFF
Disabled
On Bell cut-off
See table
See table
No
See table
See table
No
OFF
Disabled
Disabled
No EOL
Disabled
Disabled
Future use
OFF
See table
See table
See table
See table
Disabled
Disabled
24Hrs
Disabled
Bold = Default setting
ON
Enabled
On zone closure
See table
See table
Yes
See table
See table
Yes
Bold = Default setting
ON
Enabled
Enabled
Use EOL resistors
Enabled
Enabled
Future use
Bold = Default setting
ON
See table
See table
See table
See table
Enabled
Enabled
80 minutes
Enabled
Programming Guide